Chapter 7 Alternating Current

Practice questions

Power is transmitted at 22 kV instead of 2.2 kV through the same line. By what factor is the line loss reduced (same power delivered)?

  1. 10
  2. √10
  3. 1000
  4. 100
Answer and explanation

Answer: D

I = P/V falls by a factor of 10, and the loss I²R falls by 10² = 100.

Which loss in a transformer is reduced by winding the primary and secondary coils one over the other?

  1. Flux leakage
  2. Eddy current loss
  3. Hysteresis loss
  4. Copper (I²R) loss
Answer and explanation

Answer: A

Winding the coils over each other makes almost all the primary flux pass through the secondary, reducing flux leakage. Laminations reduce eddy currents, suitable core material reduces hysteresis, and thick wire reduces I²R loss.

A transformer steps 220 V up to 3300 V. If the primary has 60 turns, how many turns does the secondary have?

  1. 4 turns
  2. 900 turns
  3. 3300 turns
  4. 15 turns
Answer and explanation

Answer: B

N_s = N_p × V_s/V_p = 60 × 3300 ÷ 220 = 60 × 15 = 900 turns.

A circuit takes 5 A at 200 V with a power factor of 0.8. What average power does it consume?

  1. 1000 W
  2. 1250 W
  3. 640 W
  4. 800 W
Answer and explanation

Answer: D

P = VI cos φ = 200 × 5 × 0.8 = 800 W.

For the circuit of the previous question on a 230 V supply at resonance, what is the rms voltage across the LC combination?

  1. 230 V
  2. 115 V
  3. Zero
  4. 460 V
Answer and explanation

Answer: C

At resonance V_L = V_C and they are opposite in phase, so the voltage across the L and C together is zero; the whole 230 V appears across R.

A series LCR circuit has L = 2.0 H, C = 50 μF and R = 40 Ω. What is the resonant angular frequency?

  1. 100 rad s⁻¹
  2. 10 rad s⁻¹
  3. 1000 rad s⁻¹
  4. 16 rad s⁻¹
Answer and explanation

Answer: A

ω₀ = 1/√(LC) = 1/√(2.0 × 50 × 10⁻⁶) = 1/√(10⁻⁴) = 1 ÷ 0.01 = 100 rad s⁻¹ (about 16 Hz).

For a series circuit with R = 4 Ω, X_L = 9 Ω and X_C = 6 Ω, the phase angle φ between current and voltage is about

  1. 53°, current leading
  2. 37°, current lagging
  3. 53°, current lagging
  4. 37°, current leading
Answer and explanation

Answer: B

tan φ = (X_C − X_L)/R = (6 − 9)/4 = −3/4, so |φ| = tan⁻¹(0.75) ≈ 37°. Being negative (X_L > X_C), the circuit is inductive and the current lags.

In a series LCR circuit, V_R = 80 V, V_L = 120 V and V_C = 60 V (rms). What is the supply voltage?

  1. 260 V
  2. 100 V
  3. 140 V
  4. 200 V
Answer and explanation

Answer: B

V = √[V_R² + (V_L − V_C)²] = √[80² + 60²] = √(6400 + 3600) = √10 000 = 100 V. The voltages must be added as phasors.

A resistor of 40 Ω and a capacitor of reactance 30 Ω are in series on 100 V rms. What is the current?

  1. 1.43 A
  2. 2 A
  3. 2.5 A
  4. 3.33 A
Answer and explanation

Answer: B

Z = √(40² + 30²) = √2500 = 50 Ω. I = V/Z = 100 ÷ 50 = 2 A.

In an ac circuit the current lags the voltage by π/2. The circuit contains

  1. only a resistor
  2. only a capacitor
  3. a resistor and a capacitor
  4. only an inductor
Answer and explanation

Answer: D

A lag of exactly π/2 occurs for a pure inductor. A pure capacitor gives a lead of π/2, a resistor gives no phase difference, and an RC circuit gives a lead between 0 and π/2.

A capacitor allows 0.2 A to flow from a 50 Hz supply. If the supply frequency is changed to 200 Hz at the same voltage, the current becomes

  1. 0.05 A
  2. 0.2 A
  3. 0.4 A
  4. 0.8 A
Answer and explanation

Answer: D

X_C = 1/(2πνC) ∝ 1/ν. Making ν four times larger reduces X_C to a quarter, so the current becomes four times larger: 4 × 0.2 = 0.8 A.

A 0.2 H inductor and a 100 μF capacitor are each connected in turn to the same 50 Hz supply. Which statement is correct?

  1. The inductor draws more current
  2. Both draw the same current
  3. The capacitor draws more current
  4. Neither draws any current
Answer and explanation

Answer: C

X_L = 2π × 50 × 0.2 ≈ 62.8 Ω and X_C = 1 ÷ (2π × 50 × 100 × 10⁻⁶) ≈ 31.8 Ω. The smaller reactance passes the larger current, so the capacitor draws about twice as much.

Assertion (A): A household supply described as 220 V has a peak voltage of about 311 V. Reason (R): For a sinusoidal voltage the peak value is √2 times the rms value, and stated ac values are rms values.

  1. Both A and R are true, and R is the correct explanation of A
  2. Both A and R are true, but R is not the correct explanation of A
  3. A is true, but R is false
  4. A is false, but R is true
Answer and explanation

Answer: A

Both are true. The 220 V is the rms value, and v_m = √2 × 220 ≈ 311 V. R explains A.

An ac voltage is v = 311 sin (314t) V. Which statement is correct?

  1. The rms voltage is 311 V and the frequency 314 Hz
  2. The rms voltage is 220 V and the frequency 50 Hz
  3. The rms voltage is 220 V and the frequency 314 Hz
  4. The rms voltage is 440 V and the frequency 50 Hz
Answer and explanation

Answer: B

V = 311/√2 ≈ 220 V. ω = 314 rad s⁻¹ = 2πν gives ν = 314 ÷ 6.28 = 50 Hz.

A lamp rated 60 W, 240 V is connected to a 240 V ac supply. What is the peak current through it?

  1. 0.25 A
  2. 0.18 A
  3. 0.35 A
  4. 0.5 A
Answer and explanation

Answer: C

rms current I = P/V = 60 ÷ 240 = 0.25 A. Peak current = √2 × 0.25 ≈ 0.35 A.

Assertion (A): A step-up transformer increases the voltage without violating the conservation of energy. Reason (R): In a step-up transformer, the current in the secondary is smaller than that in the primary in the same proportion.

  1. Both A and R are true, and R is the correct explanation of A
  2. Both A and R are true, but R is not the correct explanation of A
  3. A is true, but R is false
  4. A is false, but R is true
Answer and explanation

Answer: A

Both are true. Since V_sI_s = V_pI_p (ideally), raising V by the turns ratio lowers I by the same ratio, so power is not increased. R explains A.

Why does a transformer not work with a steady dc supply?

  1. The core would melt
  2. The primary resistance becomes infinite
  3. dc cannot magnetise iron
  4. A steady current gives a constant flux, so no emf is induced in the secondary
Answer and explanation

Answer: D

Induction needs a changing flux. A steady current in the primary produces a constant flux in the core, so dφ/dt = 0 and the secondary gets no emf.

The core of a transformer is laminated in order to reduce

  1. eddy current losses
  2. flux leakage
  3. copper losses in the windings
  4. the turns ratio
Answer and explanation

Answer: A

Thin insulated laminations break up the paths of the circulating (eddy) currents induced in the iron core, reducing the heating they cause.

In an ideal step-down transformer with turns ratio N_p : N_s = 20 : 1, the primary current is 0.5 A. What is the secondary current?

  1. 0.025 A
  2. 20 A
  3. 10 A
  4. 40 A
Answer and explanation

Answer: C

I_s/I_p = N_p/N_s = 20, so I_s = 20 × 0.5 = 10 A.

A transformer has 100 turns in the primary and 500 turns in the secondary. A 220 V supply is applied to the primary. What is the secondary voltage (ideal transformer)?

  1. 44 V
  2. 1100 V
  3. 220 V
  4. 11 000 V
Answer and explanation

Answer: B

V_s = V_p × N_s/N_p = 220 × 500 ÷ 100 = 1100 V. It is a step-up transformer.