Renewable Energy

Practice questions

Which measure best helps a grid absorb a large share of solar and wind?

  1. Switching off all dispatchable plants permanently
  2. Storage, flexible demand and links to other regions
  3. Building only solar panels in one place
  4. Removing all transmission lines to avoid losses
Answer and explanation

Answer: B

Variable sources need balancing. Storage, demand that can shift and wider interconnection reduce the mismatch between supply and demand.

A plant sends out 500 MWh and 4% is lost in transmission. How much is delivered?

  1. 520 MWh
  2. 496 MWh
  3. 20 MWh
  4. 480 MWh
Answer and explanation

Answer: D

Delivered = 500 × 0.96 = 480 MWh. Adding the loss instead of subtracting gives 520.

Which of these sources is dispatchable?

  1. Solar PV in the afternoon, because it is brightest at that time of day
  2. Hydro with a reservoir, because water can be released when needed
  3. Wind, because it always blows harder at night than during the day
  4. Run-of-river hydro, because river flow never changes with the season
Answer and explanation

Answer: B

A reservoir lets operators choose when to generate. Solar, wind and run-of-river output follow nature, not demand.

A region generates 80 TWh (illustrative): 16 from solar and 24 from wind, the rest from fossil fuels. What share is variable renewable?

  1. 20%
  2. 30%
  3. 50%
  4. 40%
Answer and explanation

Answer: C

Variable renewable = 16 + 24 = 40 TWh. Share = 40 ÷ 80 = 50%.

A farm has 50 MW with a capacity factor of 24% and another has 30 MW with a capacity factor of 30%. What is the combined capacity factor?

  1. 26.25%
  2. 27%
  3. 54%
  4. 21%
Answer and explanation

Answer: A

Average powers: 12 MW and 9 MW, total 21 MW. Combined CF = 21 ÷ 80 = 0.2625 = 26.25%. Averaging 24% and 30% gives the wrong 27%.

A system supplies 10,000 kWh. The displaced grid factor is 0.8 kg CO₂/kWh and the system's lifecycle factor is 0.1 kg CO₂/kWh. What is the net CO₂ avoided?

  1. 8 tonnes
  2. 9 tonnes
  3. 7 tonnes
  4. 0.7 tonnes
Answer and explanation

Answer: C

Net factor = 0.8 − 0.1 = 0.7 kg/kWh; 10,000 × 0.7 = 7,000 kg = 7 tonnes. The 8 tonnes ignores the lifecycle emissions.

Which statement about the emissions of renewable electricity is most accurate?

  1. Building the equipment causes some emissions, usually fewer per kWh than fossil fuel plants
  2. Renewable systems cause no emissions at all, whether in building, running or retiring
  3. Renewable systems cause more emissions per kWh than coal plants over their lives
  4. Emissions arise only while the system stands idle at night, never while running
Answer and explanation

Answer: A

Lifecycle assessments count emissions from manufacture and construction. They are normally much lower per unit of electricity than for fossil fuel plants, but they are not zero.

A system costs ₹90,000 and saves ₹7,500 a year. What is its simple cost payback?

  1. 8.3 years
  2. 675 years
  3. 12 years
  4. 1.2 years
Answer and explanation

Answer: C

Payback = 90,000 ÷ 7,500 = 12 years. 8.3 is the saving as a percentage of the cost (7,500 ÷ 90,000 = 8.3%), not a payback period.

A plant displaces 500 MWh of grid electricity at an illustrative 0.9 kg CO₂ per kWh. How much CO₂ is avoided?

  1. 450 kg
  2. 450 tonnes
  3. 45 tonnes
  4. 4,500 tonnes
Answer and explanation

Answer: B

500 MWh = 500,000 kWh; 500,000 × 0.9 = 450,000 kg = 450 tonnes.

A system has an embodied energy of 6,000 kWh and produces 2,000 kWh a year. What is its energy payback time?

  1. 12 years
  2. 0.33 years
  3. 1.5 years
  4. 3 years
Answer and explanation

Answer: D

Energy payback = 6,000 ÷ 2,000 = 3 years. Dividing the other way gives 0.33, which has no sensible meaning here.

A storage unit is rated 50 kW and 200 kWh. For how long can it supply its full power?

  1. 4 hours
  2. 0.25 hours
  3. 10,000 hours
  4. 150 hours
Answer and explanation

Answer: A

Time = capacity ÷ power = 200 kWh ÷ 50 kW = 4 hours. Dividing the other way gives 0.25, a unit trap.

A load of 2 kWh a day needs 3 days of autonomy with a permitted depth of discharge of 50%. What storage is required?

  1. 6 kWh
  2. 12 kWh
  3. 3 kWh
  4. 1.33 kWh
Answer and explanation

Answer: B

Storage = 2 × 3 ÷ 0.5 = 12 kWh. Without dividing by the depth of discharge the answer would be 6 kWh, which is the trap.

A 5 kWh battery may be discharged to a depth of 60%. For how long can it run a 500 W load?

  1. 10 hours
  2. 3 hours
  3. 5 hours
  4. 6 hours
Answer and explanation

Answer: D

Usable energy = 5 × 0.60 = 3 kWh = 3,000 Wh. Hours = 3,000 ÷ 500 = 6.

Two identical 12 V, 150 Ah batteries are joined in series. What does the pair provide?

  1. 24 V and 150 Ah
  2. 12 V and 300 Ah
  3. 24 V and 300 Ah
  4. 12 V and 150 Ah
Answer and explanation

Answer: A

Series adds voltages and keeps the ampere-hours of one battery, so 24 V and 150 Ah. The stored energy is 3.6 kWh, twice that of one battery.

How much energy does a 24 V, 200 Ah battery store?

  1. 8.3 kWh
  2. 48 kWh
  3. 4.8 kWh
  4. 0.48 kWh
Answer and explanation

Answer: C

Energy = 24 × 200 = 4,800 Wh = 4.8 kWh. The value 8.3 comes from dividing 200 by 24.

A unit has 36,000 MJ of heat in its fuel and converts 25% of it to electricity. How many kWh of electricity result?

  1. 9,000 kWh
  2. 10,000 kWh
  3. 900 kWh
  4. 2,500 kWh
Answer and explanation

Answer: D

Electrical energy = 36,000 × 0.25 = 9,000 MJ; 9,000 ÷ 3.6 = 2,500 kWh. The value 9,000 forgets the unit conversion and 10,000 forgets the efficiency.

Water at 10 kg/s is cooled by 30 K in a geothermal heat exchanger (specific heat 4.2 kJ/kg/K). How much heat is extracted?

  1. 126 kW
  2. 12,600 kW
  3. 1,260 kW
  4. 12.6 kW
Answer and explanation

Answer: C

Heat = 10 × 4.2 × 30 = 1,260 kW. Keep the temperature drop in kelvin and the specific heat in kJ so the answer is in kW.

A plant digests 80 kg of dung a day and each kilogram yields 0.04 m³ of gas. How much gas is produced per day?

  1. 3.2 m³
  2. 32 m³
  3. 0.32 m³
  4. 2,000 m³
Answer and explanation

Answer: A

Gas = 80 × 0.04 = 3.2 m³. The value 2,000 comes from dividing 80 by 0.04, which is the wrong operation here.

Which statement about biogas is correct?

  1. Its fuel is mainly hydrogen, made by splitting water in sunlight
  2. Its fuel is mainly carbon monoxide, made by burning dung fast
  3. Its fuel is mainly nitrogen, released as the dung dries out
  4. Its fuel is mainly methane, made by microbes without oxygen
Answer and explanation

Answer: D

Biogas is produced by anaerobic digestion and its combustible part is mainly methane; the other main gas is carbon dioxide.

A wood-fired unit burns 500 kg of wood with a calorific value of 16 MJ/kg. How much heat is released?

  1. 31.25 MJ
  2. 8,000 MJ
  3. 80,000 MJ
  4. 800 MJ
Answer and explanation

Answer: B

Heat = mass × calorific value = 500 × 16 = 8,000 MJ. Dividing 500 by 16 gives the wrong 31.25.

Privacy · Terms · Refunds · Delivery