Numbers appear in climatology questions in a few repeating forms. Learn the formula for each one and a standard way of setting out the working, and the marks become easy. In this lesson the saturation values for air are illustrative figures chosen for practice, not tables to memorise.

Formulas

  • Relative humidity (RH) = actual vapour content / vapour the air could hold at that temperature x 100.
  • Dew point: the temperature at which the air's capacity equals the vapour it actually holds, so that RH = 100 per cent.
  • Albedo = reflected radiation / incoming radiation (as a fraction, or x 100 for per cent).
  • Heat budget: incoming = reflected + absorbed; for a balance, absorbed = outgoing.

An illustrative capacity table

How much vapour one cubic metre of air can hold (illustrative)
TemperatureCapacity (grams)
30 degrees Celsius30
20 degrees Celsius17
10 degrees Celsius9

Warm air can hold more vapour than cold air. So cooling air raises its relative humidity, even though the vapour is unchanged, and heating air lowers it.

Worked example 1: RH and cooling

At 30 degrees Celsius a cubic metre of air holds 15 g of vapour. RH = 15 / 30 x 100 = 50 per cent. If the same air cools to 20 degrees Celsius with no vapour added or removed, its capacity falls to 17 g. RH = 15 / 17 x 100 = 88 per cent (to the nearest whole number). Cool it to 10 degrees, where capacity is 9 g: the air cannot hold 15 g, so 15 - 9 = 6 g condenses as dew or cloud, and RH is 100 per cent.

Worked example 2: dew point

Air at 30 degrees Celsius holds 9 g of vapour per cubic metre. Its RH = 9 / 30 x 100 = 30 per cent. To find the dew point, look for the temperature at which the capacity is 9 g. From the table, that is 10 degrees Celsius. So if the air cools to 10 degrees, dew forms. If another sample holds 17 g at 30 degrees, then RH = 17 / 30 x 100 = about 57 per cent and the dew point is 20 degrees.

Worked example 3: albedo

A snow field receives 1000 units of sunlight and reflects 800 units. Albedo = 800 / 1000 = 0.8, or 80 per cent. Absorbed = 1000 - 800 = 200 units. For a forest with albedo 0.2 receiving the same 1000 units, the reflected part is 200 and the absorbed part is 800. The forest absorbs four times as much (800 / 200 = 4), which is one reason snow-covered land stays cold.

Worked example 4: balancing

Of 100 units of solar energy that arrive, 30 are reflected. In a balanced budget, how many units are sent back as heat from the Earth and atmosphere? Working: absorbed = 100 - 30 = 70. For a balance, outgoing = absorbed = 70 units. If outgoing heat were only 65 units, then 70 - 65 = 5 units more would stay in the system each cycle, and temperature would rise.

Slips to avoid

  • Dividing by the actual vapour instead of the capacity.
  • Forgetting that capacity depends on temperature.
  • Calling the reflected part 'absorbed' in albedo questions.

RH = actual / capacity x 100. Dew point: capacity equals actual. Albedo = reflected / incoming. Balance: outgoing = absorbed.

— Rule to remember

Key takeaways

  • Cooling raises RH; heating lowers it.
  • At the dew point, RH is 100 per cent and condensation starts.
  • A high albedo means little absorbed heat.

Check your understanding

  1. 1. Air holds 6 g of vapour and could hold 24 g. Relative humidity is:

    1. 25 per cent
    2. 40 per cent
    3. 18 per cent
    4. 75 per cent
    Show answer

    Answer: A. 6 / 24 x 100 = 25 per cent.

  2. 2. Air at 20 degrees Celsius holds 17 g (its full capacity in the table). Its RH is:

    1. 50 per cent
    2. 90 per cent
    3. 100 per cent
    4. 17 per cent
    Show answer

    Answer: C. Actual equals capacity, so RH = 100 per cent, and 20 degrees is the dew point.

  3. 3. A surface receives 500 units and reflects 100. Its albedo is:

    1. 0.1
    2. 0.5
    3. 0.8
    4. 0.2
    Show answer

    Answer: D. 100 / 500 = 0.2, so 20 per cent is reflected.

  4. 4. When unsaturated air cools without adding or losing vapour, its relative humidity:

    1. falls
    2. rises
    3. stays the same
    4. becomes zero
    Show answer

    Answer: B. Cooling reduces the capacity while the vapour stays the same, so RH rises.

  5. 5. 100 units arrive and 35 are reflected. For balance, outgoing heat is:

    1. 65 units
    2. 35 units
    3. 135 units
    4. 100 units
    Show answer

    Answer: A. Absorbed = 100 - 35 = 65 units, and in a balance outgoing equals absorbed.