• Practice
  • About 16 min
  • 5 practice questions

Discovery of the cell and microscopy

Trace who discovered cells and the nucleus, explain how the bright field microscope, TEM and SEM work, and use resolution, magnification and micrometry formulas.

If something looks wrong, please tell us.

By the end of this lesson you can

  • Name the scientists behind the early discoveries about cells, in order.
  • Describe the light path and the two magnifications of a bright field microscope.
  • Use the formulas for resolution and magnification.
  • Compare the transmission and scanning electron microscopes.
  • Calibrate an ocular micrometre against a stage micrometre.

Every organism you study in botany, from a bacterium to a banyan tree, is built of cells. Yet cells are too small to see with the naked eye, so the story of the cell is also the story of the microscope. This lesson follows the Tamil Nadu textbook's opening sections: who saw cells first, and how microscopes let us see them in ever finer detail.

How the cell was discovered

The word cell comes from the Latin cella, a small room or compartment. The Greek thinker Aristotle already recognised that plants and animals are made of organised units, but he could not say what they were. In the 1660s Robert Hooke examined thin slices of cork and saw a honeycomb of tiny boxes, which he called cells; he described this in his book Micrographia (1665). What Hooke saw were the empty walls of dead cork cells.

  1. Anton van Leeuwenhoek saw living single-celled organisms and called them animalcules.
  2. Robert Brown described the spherical body in plant cells and named it the nucleus (the textbook gives 1831-39).
  3. H. J. Dutrochet (1824), a French scientist, first put forward an idea of a cell theory.
  4. Matthias Schleiden (German botanist) and Theodor Schwann (German zoologist) outlined the main features of the cell theory.
  5. Rudolf Virchow (1858) added that all living cells arise from pre-existing cells by cell division.

The bright field (compound) microscope

The name microscope comes from the Greek mikros (small) and skopein (to see). A microscope with several lenses is a compound microscope; the textbook credits its invention to Z. Jansen. The everyday version is the bright field microscope, in which light passes straight through the specimen. Staining the specimen increases contrast between its parts.

Light path in a bright field microscope

  1. Light source A CFL or LED lamp below the stage
  2. Condenser Focuses light on the specimen
  3. Specimen on stage Mounted on a microslide
  4. Objective lens Primary magnification: real, inverted image
  5. Eyepiece Secondary magnification: virtual image seen by the eye

The objective lenses (the textbook lists 5X, 10X, 45X and 100X) sit on a rotating nosepiece. The total magnification is the product of the objective and eyepiece powers.

Resolution, numerical aperture and magnification

Resolution (resolving power) is the ability of a lens to show two close points as separate: the finest detail it can reveal. It depends on the wavelength of light (λ) and the numerical aperture (NA), an optical constant of the lens. The higher the NA, the better the resolving power. Magnification is the optical increase in the size of an image compared with how it looks to the unaided eye.

Resolution = 0.61 λ ÷ NA (smaller value = finer detail). Magnification = size of image under the microscope ÷ size seen with the naked eye.

Worked example 1: resolution

Green light of wavelength 550 nm is used with an objective of NA 1.25. Resolution = 0.61 × 550 ÷ 1.25. First 0.61 × 550 = 335.5. Then 335.5 ÷ 1.25 = 268.4 nm. Check: 268.4 × 1.25 = 335.5. So two points closer than about 0.27 µm cannot be told apart. Using a lens with a higher NA would make this number smaller, which means better resolution.

Worked example 2: total magnification

A student uses the 45X objective with a 10X eyepiece. Total magnification = 45 × 10 = 450 times. Switching to the 100X objective gives 100 × 10 = 1000 times.

Electron microscopes

The electron microscope, first built by Ernst Ruska (1931), uses a beam of accelerated electrons instead of light. Because electrons have a far shorter wavelength, its resolving power is enormously greater than that of a light microscope, and it reveals the ultrastructure of cells and organelles. Specimens are dehydrated and coated with electron-dense metals such as gold or palladium so they withstand the beam and give contrast.

TEM and SEM compared (values as given in the Tamil Nadu textbook)
FeatureTransmission EM (TEM)Scanning EM (SEM)
How the image formsElectrons pass through the specimen onto a fluorescent screenA fine electron beam scans the surface; released electrons are detected
ImageTwo-dimensionalThree-dimensional surface view
Magnification1-3 lakh timesAbout 2 lakh times
Resolution2-10 Å (higher)5-20 nm (lower than TEM)
Used forViruses, mycoplasma, internal organellesSurfaces of cells, pollen, insects

Micrometry: measuring cells

Two scales are used. The ocular micrometre is a glass disc inside the eyepiece with 100 divisions that have no fixed value. The stage micrometre is a slide whose line of about 1 mm is divided into 100 parts, so one division is 10 µm. Lining up the two scales lets you work out the value of one ocular division.

Value of one ocular division = (number of stage divisions ÷ number of ocular divisions) × 10 µm

Worked example 3: calibrating the eyepiece (made-up readings)

Suppose 40 ocular divisions coincide exactly with 12 stage divisions. One ocular division = (12 ÷ 40) × 10 = 0.3 × 10 = 3 µm. If a cell then spans 15 ocular divisions, its length is 15 × 3 = 45 µm.

Key takeaways: Hooke named the cell, Brown named the nucleus and Virchow added that cells come from cells. A bright field microscope gives a real image from the objective and a virtual image from the eyepiece. Resolution = 0.61λ/NA; electron microscopes resolve far finer detail, TEM in 2D and SEM in 3D. Micrometry converts eyepiece divisions to micrometres.

Check your understanding

  1. 1. Who added to the cell theory the idea that all living cells arise from pre-existing cells?

    1. Robert Hooke
    2. Rudolf Virchow
    3. Robert Brown
    4. Anton van Leeuwenhoek
    Show answer

    Answer: B. Rudolf Virchow (1858) stated that cells arise from pre-existing cells by cell division. Hooke named the cell, Brown named the nucleus and Leeuwenhoek saw animalcules.

  2. 2. The image formed by the objective lens of a compound microscope is:

    1. virtual and erect
    2. virtual and inverted
    3. real and erect
    4. real and inverted
    Show answer

    Answer: D. The objective gives the primary magnification, a real and inverted image, which the eyepiece then enlarges into a virtual image.

  3. 3. Light of wavelength 500 nm is used with a lens of NA 1.0. What is the resolution?

    1. 305 nm
    2. 500 nm
    3. 820 nm
    4. 61 nm
    Show answer

    Answer: A. Resolution = 0.61 × λ ÷ NA = 0.61 × 500 ÷ 1.0 = 305 nm.

  4. 4. Which statement about the scanning electron microscope is correct?

    1. It gives a two-dimensional image of thin sections
    2. It uses visible light
    3. It gives a three-dimensional image and has lower resolving power than TEM
    4. It has higher resolving power than TEM
    Show answer

    Answer: C. SEM scans the surface and gives a 3D image; its resolution (5-20 nm) is lower than that of TEM (2-10 Å).

  5. 5. In calibration, 25 ocular divisions coincide with 5 stage divisions. What is the value of one ocular division?

    1. 5 µm
    2. 0.2 µm
    3. 50 µm
    4. 2 µm
    Show answer

    Answer: D. Value = (stage divisions ÷ ocular divisions) × 10 µm = (5 ÷ 25) × 10 = 0.2 × 10 = 2 µm.

Privacy · Terms · Refunds · Delivery