Revision notes

Chapter 5 Magnetism and Matter: Foundation

The key points, rules to remember, tables and diagrams from all 5 lessons, on one page for quick revision. To keep a copy, use your browser's Print and choose "Save as PDF".

Lesson 1

The bar magnet, field lines and the equivalent solenoid

Field lines of a bar magnet and of an electric dipole

  • Bar magnet
    • Closed loops
    • Outside: N to S; inside: S to N
    • No starting or ending points
    • Net flux through any closed surface is zero
  • Electric dipole
    • Begin on +q, end on −q
    • Do not continue through the charges
    • Have sources and sinks (charges)
    • Net flux through a surface enclosing +q is not zero
Far from the source the two patterns look alike.

Far axial field of a bar magnet or solenoid of magnetic moment m: B = (μ₀/4π)(2m/r³), along m. The bar magnet's moment is the moment of the solenoid that produces the same field.

Ways to recognise an equivalent solenoid

  • Field pattern
    • Iron filings make the same pattern outside both
  • Compass test
    • A needle moved around either is deflected the same way
  • Cutting
    • Each piece is a smaller magnet with two ends
  • Far axial field
    • Both give (μ₀/4π)(2m/r³)
  • Like poles repel, unlike poles attract; poles always come in pairs - no monopoles.
  • Magnetic field lines are closed loops, never cross, and their density shows field strength.
  • A bar magnet is equivalent to a solenoid with m = NIA; far axial field (μ₀/4π)(2m/r³).
Read the full lesson

Lesson 2

Magnetic dipole in a uniform field and the electrostatic analogy

τ = m × B, |τ| = mB sin θ, where θ is the angle between m and B. The torque tends to turn m into line with B.

U = −m · B = −mB cos θ. Work to turn the magnet from θ₁ to θ₂: W = mB (cos θ₁ − cos θ₂).

A magnet in a uniform field
Angle θTorque mB sin θEnergy −mB cos θEquilibrium
0° (along B)0−mB (minimum)Stable
90°mB (maximum)0Not in equilibrium
180° (against B)0+mB (maximum)Unstable
The dipole analogy
QuantityElectric dipoleMagnetic dipole (short magnet)
Constant1/ε₀μ₀
Dipole momentpm
Axial field (r ≫ l)2p/(4πε₀r³)μ₀ 2m/(4πr³)
Equatorial field (r ≫ l)−p/(4πε₀r³)−μ₀ m/(4πr³)
Torque in a uniform fieldp × Em × B
Energy in a uniform field−p · E−m · B

Short bar magnet, distance r ≫ its size: B_axial = (μ₀/4π)(2m/r³) along m; B_equatorial = (μ₀/4π)(m/r³) opposite to m.

Using the analogy

  1. Start from the electric-dipole result For example, axial field 2p/(4πε₀r³).
  2. Replace p by m The dipole moment of the magnet.
  3. Replace 1/(4πε₀) by μ₀/4π That is, by 10⁻⁷ T m A⁻¹.
  4. Read off the magnetic result Axial field μ₀2m/(4πr³).
  • Uniform field: no net force; τ = m × B; U = −m · B (zero at 90°).
  • Stable equilibrium along B (U = −mB); unstable against B (U = +mB).
  • Short magnet: axial (μ₀/4π)(2m/r³), equatorial (μ₀/4π)(m/r³), from the electric-dipole formulas with p → m and 1/ε₀ → μ₀.
Read the full lesson

Lesson 3

Gauss's law for magnetism

Magnetic flux φ_B = Σ B · ΔS. SI unit: weber (Wb), 1 Wb = 1 T m². So the tesla is also written Wb m⁻².

Gauss's law for magnetism: the net magnetic flux through any closed surface is zero. φ_B = Σ B · ΔS = 0 (over all elements of the closed surface).

Gauss's law in electrostatics and in magnetism

  • Electrostatics
    • Σ E · ΔS = q/ε₀
    • Flux measures the enclosed charge
    • Field lines begin and end on charges
    • Isolated charges exist
  • Magnetism
    • Σ B · ΔS = 0
    • Always zero, whatever is enclosed
    • Field lines are closed loops
    • No isolated poles (monopoles) are known

Is this a possible magnetic field pattern?

  • Any lines start or end at a point?
    • Yes: not magnetic (net flux ≠ 0)
  • A closed loop around empty space?
    • Yes: not a static magnetic field (Ampere's law)
  • Lines crossing?
    • Yes: impossible for any field
  • Closed loops each enclosing a current, no crossings
    • Possible magnetic field
  • Magnetic flux φ = B · ΔS, measured in webers (1 Wb = 1 T m²).
  • Net magnetic flux through any closed surface is zero: there are no magnetic monopoles.
  • Magnetic field lines are closed loops; patterns with sources, sinks or loops around empty space are not static magnetic fields.
Read the full lesson

Lesson 4

Magnetisation, magnetic intensity and susceptibility

M = m_net / V. M is a vector with dimensions [L⁻¹ A]; SI unit A m⁻¹.

H = B/μ₀ − M, so B = μ₀(H + M). H has the same unit as M, A m⁻¹. In a long solenoid, H = nI, whatever the core.

M = χH, where χ is the dimensionless magnetic susceptibility. Then B = μ₀(1 + χ)H = μ₀μr H = μH, with relative permeability μr = 1 + χ and permeability μ = μ₀μr.

From the current in the windings to the field in the core

  1. Current I in n turns per metre Sets the magnetic intensity H = nI.
  2. Material responds Magnetisation M = χH.
  3. Total field B = μ₀(H + M) = μ₀μr H.
Magnetic quantities of materials
QuantitySymbolUnitRelation
MagnetisationMA m⁻¹Net magnetic moment per unit volume
Magnetic intensityHA m⁻¹H = B/μ₀ − M; H = nI in a solenoid
SusceptibilityχNoneM = χH
Relative permeabilityμrNoneμr = 1 + χ
PermeabilityμT m A⁻¹μ = μ₀μr; B = μH
  • M = magnetic moment per unit volume (A m⁻¹).
  • B = μ₀(H + M); in a solenoid H = nI.
  • M = χH; μr = 1 + χ; μ = μ₀μr; B = μH.
  • χ: small negative (dia), small positive (para), large positive (ferro).
Read the full lesson

Lesson 5

Diamagnetism, paramagnetism and ferromagnetism

Classes of magnetic materials (ε is a small positive number)
PropertyDiamagneticParamagneticFerromagnetic
Susceptibility χ−1 ≤ χ < 0 (small, negative)0 < χ < ε (small, positive)χ ≫ 1
Relative permeability μr0 ≤ μr < 1Slightly more than 1μr ≫ 1 (can exceed 1000)
Permeability μμ < μ₀μ > μ₀μ ≫ μ₀
In a non-uniform fieldMoves weak-ward (repelled)Moves strong-ward (weakly attracted)Moves strong-ward (strongly attracted)
Field lines in the sampleSlightly pushed outSlightly concentratedStrongly concentrated
ExamplesBismuth, copper, lead, silicon, water, NaCl, nitrogen (at STP)Aluminium, sodium, calcium, oxygen (at STP), copper chlorideIron, cobalt, nickel, gadolinium

Magnetising a ferromagnet

  1. Random domains Each domain magnetised, but directions random: no net M.
  2. Field applied Domains along the field grow; others shrink and turn.
  3. Strong field Domains merge into a single giant domain along the field.
  4. Field removed Hard ferromagnet keeps its magnetisation; soft ferromagnet loses it.

Hard and soft ferromagnetic materials

  • Hard (e.g. alnico, lodestone)
    • Keeps magnetisation after the field is removed
    • Used for permanent magnets
    • Used in compass needles
  • Soft (e.g. soft iron)
    • Magnetisation disappears when the field is removed
    • Used for electromagnet cores
    • Easily magnetised and demagnetised
  • Diamagnetic: χ small negative; no permanent atomic moments; induced moments oppose the field; universal but weak; superconductors are perfect diamagnets.
  • Paramagnetic: χ small positive; permanent moments partly aligned against thermal agitation; better aligned at low temperature.
  • Ferromagnetic: χ ≫ 1; domains; hard materials make permanent magnets, soft ones make electromagnet cores; above a high enough temperature they become paramagnetic.
Read the full lesson

Privacy · Terms · Refunds · Delivery