Measuring ozone, Dobson units and common myths

Learn how scientists measure the ozone layer, convert Dobson units to thickness, work out a percentage change, and spot the most common mistakes people make about the ozone hole.

If something looks wrong, please tell us.

Claims about the ozone layer are only useful if the layer can be measured. Scientists use instruments on the ground, on balloons and on satellites. The result is usually reported in a special unit, the Dobson unit. This lesson shows how to read it, how to do two small calculations, and which popular beliefs about ozone are wrong. Exams like to place these beliefs in the options.

How ozone is measured

  • Ground stations: a spectrophotometer looks at sunlight and compares how much UV of different wavelengths gets through. The more ozone above, the less UV-B arrives. The instrument named after G. M. B. Dobson was one of the first.
  • Balloons: a small instrument called an ozonesonde is carried up by a balloon and measures ozone at each height.
  • Satellites: instruments in space look down at sunlight scattered from the atmosphere and map ozone over the whole globe.

The Dobson unit

Total ozone in a column of air above a place is measured in Dobson units (DU). Imagine bringing all the ozone in that column down to the ground and squeezing it to the pressure and temperature we usually quote for gases at sea level. It would form a layer only a few millimetres thick. One Dobson unit equals a layer 0.01 millimetre thick. So a reading of 300 DU means a layer of 300 × 0.01 = 3 mm.

1 DU = 0.01 mm of pure ozone at standard conditions. To get millimetres, divide the DU reading by 100.

Worked examples

Example 1. A station reads 280 DU. How thick would the ozone layer be if it were all brought down to standard conditions? Working: thickness = 280 × 0.01 mm = 2.8 mm. Check by dividing: 280 ÷ 100 = 2.8. That is a very thin layer for the whole column of air above the station.

Example 2. In a certain spring, the reading at a station is 300 DU before the season and 240 DU later (illustrative values). What is the percentage fall? Working: fall = 300 − 240 = 60 DU. Percentage = 60 ÷ 300 × 100 = 20%. The percentage is always worked out from the starting value, not from the final value.

Example 3. Ozone then recovers from 240 DU to 300 DU. Is the percentage rise also 20%? Working: rise = 60 DU. Percentage rise = 60 ÷ 240 × 100 = 25%. The rise is 25%, not 20%, because the starting value is now smaller. This is a common trap in percentage questions.

Common myths and mix-ups

MythWhat is actually true
The ozone hole is a real hole in the sky.It is a large area where the ozone layer is much thinner than normal, not an empty space.
The ozone hole causes global warming.They are different problems. Ozone loss lets in more UV-B; global warming comes from greenhouse gases trapping heat.
CFCs are too heavy to reach the stratosphere.The air is well mixed, so even heavy gases are carried up over time.
Ozone is bad everywhere.It protects in the stratosphere and is a pollutant at ground level.
The ozone problem is solved the day a chemical is banned.Chemicals already in the air last for decades, so recovery is slow.

Key takeaways: ozone is measured from the ground, from balloons and from satellites. One Dobson unit is a layer 0.01 mm thick at standard conditions, so divide by 100 to get millimetres. Work percentage changes from the starting value. The ozone hole is a thinning, it is not the same thing as global warming, and recovery takes decades.

Check your understanding

  1. 1. A reading of 320 DU corresponds to a layer of ozone how thick at standard conditions?

    1. 0.32 mm
    2. 3.2 mm
    3. 32 mm
    4. 320 mm
    Show answer

    Answer: B. Thickness = 320 × 0.01 mm = 3.2 mm. Dividing the DU reading by 100 gives millimetres.

  2. 2. Ozone at a station falls from 300 DU to 225 DU (illustrative). What is the percentage fall?

    1. 20%
    2. 75%
    3. 25%
    4. 30%
    Show answer

    Answer: C. Fall = 75 DU. Percentage = 75 ÷ 300 × 100 = 25%.

  3. 3. Which instrument is carried up by a balloon to measure ozone at different heights?

    1. Ozonesonde
    2. Barometer
    3. Telescope
    4. Seismograph
    Show answer

    Answer: A. An ozonesonde is a small balloon-borne instrument that records ozone at each height as it rises.

  4. 4. Which statement about the ozone hole is correct?

    1. It is an empty space in the sky
    2. It is the main cause of global warming
    3. It is caused by volcanoes alone
    4. It is an area of much thinner ozone
    Show answer

    Answer: D. The ozone hole is a region where ozone is greatly reduced, not an empty hole. It is a separate problem from global warming.

  5. 5. Ozone rises from 200 DU to 250 DU (illustrative). What is the percentage rise?

    1. 20%
    2. 25%
    3. 50%
    4. 10%
    Show answer

    Answer: B. Rise = 50 DU. Percentage = 50 ÷ 200 × 100 = 25%. The starting value, 200 DU, is the base.