- Practice
- About 28 min
- 5 practice questions
Optical instruments: microscopes, telescopes, spectrometer and the eye
Find the magnification and resolving power of simple and compound microscopes and telescopes, describe the spectrometer and its use, and calculate correcting lenses for myopia and hypermetropia.
If something looks wrong, please tell us.
By the end of this lesson you can
- Derive m = 1 + D/f (near point) and m = D/f (normal focusing) for a simple microscope.
- Write the resolving power of a microscope and a telescope and explain the oil-immersion objective.
- Find the magnification of a compound microscope and an astronomical telescope.
- Describe the spectrometer, its adjustments and the measurement of A and D for a prism.
- Explain the focusing of the eye and find the correcting lenses for myopia and hypermetropia.
Optical instruments extend what our eyes can see. A healthy eye sees clearly from the near point D = 25 cm (least distance of distinct vision) to the far point at infinity. The eye is most relaxed when the image is at infinity and works hardest when the image is at the near point.
Simple microscope
A simple microscope is a convex lens of short focal length with the object placed inside F, giving an erect, magnified, virtual image. Near point focusing (image at D): with v = −D, m = v/u = D/u, and using the lens equation m = 1 − v/f, so m = 1 + D/f. Normal focusing (image at infinity, most relaxed): the linear magnification is meaningless, so we use angular magnification m = θᵢ/θ₀, where θ₀ = h/D is the angle the object subtends at the eye when placed at the near point, and θᵢ = h/f is the angle with the lens. So m = D/f, one less than for near point focusing but more comfortable to view.
Worked example 1: a reading lens
A reader with D = 25 cm uses a lens of focal length 4.0 cm. Near point: m = 1 + 25/4.0 = 7.25. The object distance: 1/u = 1/v − 1/f = −1/25 − 1/4.0 = −(4 + 25)/100 = −29/100, so u = −3.45 cm. Normal focusing: m = 25/4.0 = 6.25, with the print at the focus, 4.0 cm away. So the lens must be held between 3.45 cm and 4.0 cm from the print.
Resolving power of microscope and telescope
In a microscope the object is just beyond f and the image forms at v, so the radius of the central disc in the image is r₀ = 1.22λv/a. The smallest separation on the object that can be resolved is d_min = r₀/m with m = v/u, giving d_min = 1.22λu/a ≈ 1.22λf/a. If β is the half-angle of the cone of light from the object to the objective, a = 2f sin β, so d_min = 1.22λ/(2 sin β). Filling the space between object and objective with oil of index n reduces it further: d_min = 1.22λ/(2n sin β) = 1.22λ/(2 NA), where NA = n sin β is the numerical aperture. The resolving power is R_M = 1/d_min = 2n sin β/(1.22λ). For a telescope, R_T = 1/r₀ = a/(1.22λf).
Worked example 2: oil immersion
With λ = 500 nm and sin β = 0.90: in air (n = 1), d_min = 1.22 × 500 × 10⁻⁹/(2 × 0.90) = 3.4 × 10⁻⁷ m = 0.34 µm. In oil (n = 1.5, NA = 1.35), d_min = 1.22 × 500 × 10⁻⁹/(2 × 1.35) = 2.3 × 10⁻⁷ m = 0.23 µm: finer detail can be seen.
Compound microscope
The objective (near the object) forms a real, inverted, magnified image inside the focus of the eyepiece, which then acts as a simple microscope and gives a large virtual image, inverted with respect to the object. If L is the tube length (from the focus of the objective to the focus of the eyepiece), similar triangles give the objective's magnification m_o = L/f_o. The eyepiece gives m_e = 1 + D/f_e (near point) or D/f_e (normal). Total: m = (L/f_o)(1 + D/f_e) at the near point and m = (L/f_o)(D/f_e) in normal focusing.
Telescopes
An astronomical telescope has an objective of long focal length and large aperture and a short-focus eyepiece. The objective forms a real image of a distant object at its focus; the eyepiece magnifies it, and the final image is inverted. Angular magnification m = β/α. If h is the size of the intermediate image, α = h/f_o and β = h/f_e, so m = f_o/f_e, and the length of the telescope is about L = f_o + f_e. A terrestrial telescope adds an erecting lens so that objects on the Earth appear upright. A reflecting telescope uses a concave mirror as objective: only one surface has to be polished, the mirror can be supported over its whole back, and it weighs less than a lens of the same size. Its drawback, an eyepiece inside the tube blocking light, is overcome with a secondary mirror that sends the light out of the tube.
Worked example 3: microscope and telescope
(a) A compound microscope has f_o = 1.0 cm, f_e = 2.5 cm and tube length 15 cm (D = 25 cm). Normal focusing: m = (15/1.0)(25/2.5) = 15 × 10 = 150. Near point: m = 15 × (1 + 10) = 165. (b) A telescope has f_o = 100 cm and f_e = 4.0 cm: m = 100/4.0 = 25 and length ≈ 104 cm. Two stars 2′ (2 minutes of arc) apart to the eye appear 25 × 2′ = 50′ apart through it.
Spectrometer
A spectrometer analyses spectra, measures wavelengths and finds refractive indices. Its parts: the collimator (a convex lens with an adjustable vertical slit at its focus, giving a parallel beam; fixed to the base); the prism table (two discs with three levelling screws, read by verniers V₁ and V₂); and the telescope (astronomical type with cross-wires, turning with a circular scale). Preliminary adjustments: (a) eyepiece moved until the cross-wires are sharp; (b) telescope focused on a distant object to receive parallel rays; (c) collimator adjusted until a sharp image of the slit is seen on the cross-wires; (d) prism table levelled with a spirit level.
- Angle of the prism A: with the refracting edge facing the collimator, light reflects off both faces; the telescope is set on each reflected image (T₁, T₂). The angle between these positions is 2A.
- Angle of minimum deviation D: the refracted image is followed while the prism table is turned in the direction that lessens the deviation, until the image stops and turns back; that reading is noted. The prism is removed and the direct ray is read. The difference is D.
- Refractive index: n = sin[(A + D)/2]/sin(A/2). A hollow prism filled with a liquid gives the liquid's index the same way.
The human eye and its defects
The eye lens is flexible. The distance from lens to retina is fixed at about 2.5 cm (the image distance). Relaxed, for an object at infinity: 1/f_max = 1/2.5 − 1/(−∞), so f_max = 2.5 cm. Strained, for an object at 25 cm: 1/f_min = 1/2.5 + 1/25 = 0.44, so f_min = 2.27 cm. A change of only about 0.23 cm lets a normal eye see from infinity to 25 cm.
Common defects of vision and their correction
-
Myopia (near-sight)
- Cannot see far objects
- Eye lens focal length too short or eyeball too long
- Concave lens, f = −x (x = far point)
-
Hypermetropia (far-sight)
- Cannot see near objects
- Focal length too long or eyeball too short
- Convex lens, f = 25y/(y − 25) cm (y = near point in cm)
-
Astigmatism
- Different curvature in different planes
- Cannot see all directions equally well
- Cylindrical lens
Myopia: a person can see clearly only up to x. The correcting lens must make an object at infinity appear at x: 1/f = 1/(−x) − 1/(−∞), so f = −x, a concave lens. Hypermetropia: the near point is at y (> 25 cm). The lens must make an object at 25 cm appear at y: 1/f = 1/(−y) − 1/(−25), so f = 25y/(y − 25) cm, positive: a convex lens. Far-sightedness due to ageing is presbyopia. A person with both defects may need bifocal or progressive lenses.
Examples. (a) Far point 2.0 m: f = −2.0 m, P = −0.5 D. (b) Near point 50 cm: f = 25 × 50/(50 − 25) = 50 cm = 0.50 m, P = +2.0 D.
Simple microscope m = 1 + D/f (near point), D/f (normal). Compound m = (L/f_o)(D/f_e). Telescope m = f_o/f_e, L = f_o + f_e. d_min = 1.22λ/(2n sin β). Myopia f = −x; hypermetropia f = 25y/(y − 25).
Key takeaways
- A magnifying lens gives m = 1 + D/f at the near point and D/f with the image at infinity.
- Oil immersion increases the numerical aperture and so the resolving power of a microscope.
- Compound microscope m = (L/f_o) × m_e; astronomical telescope m = f_o/f_e with an inverted image.
- The spectrometer measures A (reflected images 2A apart) and D, giving n.
- Myopia: concave lens f = −x. Hypermetropia: convex lens f = 25y/(y − 25) cm.
Check your understanding
-
1. A magnifying glass of focal length 5.0 cm forms the final image at the near point (25 cm). Its magnification is:
- 5
- 6
- 4
- 25
Show answer
Answer: B. m = 1 + D/f = 1 + 25/5.0 = 1 + 5 = 6. (In normal focusing it would be D/f = 5.)
-
2. An astronomical telescope has an objective of focal length 150 cm and an eyepiece of 5.0 cm. Its magnification and approximate length are:
- 30, 145 cm
- 750, 155 cm
- 30, 155 cm
- 155, 30 cm
Show answer
Answer: C. m = f_o/f_e = 150/5.0 = 30. Length L ≈ f_o + f_e = 150 + 5.0 = 155 cm.
-
3. A person can see clearly only up to 80 cm. The power of the spectacle lens needed is:
- −1.25 D
- +1.25 D
- −0.80 D
- +0.80 D
Show answer
Answer: A. Myopia: f = −x = −0.80 m, so P = 1/f = −1/0.80 = −1.25 D (a concave lens).
-
4. A person's near point is 100 cm. The focal length of the spectacle lens needed to read at 25 cm is:
- −33.3 cm
- +20 cm
- +50 cm
- +33.3 cm
Show answer
Answer: D. f = 25y/(y − 25) = 25 × 100/(100 − 25) = 2500/75 = 33.3 cm, a convex lens of power +3.0 D.
-
5. In a spectrometer, the telescope readings for light reflected from the two faces of a prism differ by 120°. The angle of the prism is:
- 120°
- 30°
- 60°
- 240°
Show answer
Answer: C. The telescope turns through twice the angle of the prism between the two reflected images: 2A = 120°, so A = 60°.
Sign in to keep track of the lessons you finish.