• Foundation
  • About 22 min
  • 5 practice questions

Redox titrations, redox couples and standard electrode potentials

Explain how end points are detected in redox titrations and solve titration numericals, describe redox couples and the Daniell cell, and use standard electrode potentials to compare oxidants and reductants and predict whether a reaction is feasible.

If something looks wrong, please tell us.

By the end of this lesson you can

  • Explain how the end point is seen in permanganate, dichromate and iodine-thiosulphate titrations.
  • Calculate concentrations from redox titration data using the balanced equation.
  • Describe a redox couple and the working of the Daniell cell, including the salt bridge.
  • Use a table of standard electrode potentials to rank oxidising and reducing agents.
  • Predict whether a redox reaction between two given species is feasible.

Redox reactions are not only for classifying; they are used every day in laboratories to find the strength of solutions, and in cells to produce electricity. This lesson connects both uses to what you have learnt about electron transfer.

Redox reactions as the basis of titrations

In an acid-base titration, a pH-sensitive indicator shows the end point. In a redox titration, an oxidant of known concentration reacts with a reductant (or the reverse), and the end point is shown in one of three ways.

  • Self-indicator: the permanganate ion, MnO₄⁻, is intensely purple, while Mn²⁺ is almost colourless. While a reductant such as Fe²⁺ or C₂O₄²⁻ remains, each drop of permanganate is decolourised. Just after the last of the reductant is used up, a tiny excess gives a lasting pale pink colour. The overshoot past the equivalence point (where oxidant and reductant have reacted in exact mole ratio) is very small.
  • Redox indicator: dichromate, Cr₂O₇²⁻, has no sharp colour change of its own at the end point. An indicator such as diphenylamine is added; it is oxidised by the first excess of dichromate, giving an intense blue colour.
  • Iodine and starch: an oxidant such as Cu²⁺ is allowed to react with excess iodide, freeing iodine: 2Cu²⁺ + 4I⁻ → Cu₂I₂ (s) + I₂. The iodine is then titrated with thiosulphate: I₂ + 2S₂O₃²⁻ → 2I⁻ + S₄O₆²⁻. Starch gives a deep blue colour with iodine; the blue vanishes the moment all the iodine is used, marking the end point. (Iodine stays dissolved because it combines with iodide as I₃⁻.)

Worked example 1: a permanganate titration

25.0 mL of an iron(II) solution needs 20.0 mL of 0.0200 mol L⁻¹ KMnO₄ in acid. Find the concentration of Fe²⁺. Equation: MnO₄⁻ + 5Fe²⁺ + 8H⁺ → Mn²⁺ + 5Fe³⁺ + 4H₂O, so 1 mol MnO₄⁻ reacts with 5 mol Fe²⁺. Moles of MnO₄⁻ = 0.0200 mol L⁻¹ × 0.0200 L = 4.00 × 10⁻⁴ mol. Moles of Fe²⁺ = 5 × 4.00 × 10⁻⁴ = 2.00 × 10⁻³ mol. Concentration = 2.00 × 10⁻³ mol ÷ 0.0250 L = 0.0800 mol L⁻¹.

Worked example 2: an iodine-thiosulphate titration

A copper(II) solution is treated with excess KI, and the iodine freed needs 15.0 mL of 0.100 mol L⁻¹ sodium thiosulphate. Find the mass of copper present (molar mass of Cu = 63.5 g mol⁻¹). Thiosulphate used = 0.100 × 0.0150 = 1.50 × 10⁻³ mol. From I₂ + 2S₂O₃²⁻, moles of I₂ = 1.50 × 10⁻³ ÷ 2 = 7.50 × 10⁻⁴ mol. From 2Cu²⁺ → I₂, moles of Cu²⁺ = 2 × 7.50 × 10⁻⁴ = 1.50 × 10⁻³ mol. Mass of Cu = 1.50 × 10⁻³ × 63.5 = 0.0953 g (to 3 significant figures). Note the shortcut: overall, 1 mol S₂O₃²⁻ corresponds to 1 mol Cu²⁺.

Limitations of the oxidation number idea

The meaning of oxidation has kept changing, from oxygen addition, to electron loss, to increase in oxidation number. Oxidation numbers rest on the assumption of complete electron transfer, which is not true in covalent bonds. A more recent way to see it is that oxidation is a decrease in electron density around an atom, and reduction an increase in electron density.

Redox couples and the Daniell cell

When zinc is dipped directly into copper sulphate solution, electrons pass straight from zinc atoms to Cu²⁺ ions and the energy simply appears as heat. If we separate the two halves, the same electrons can be made to flow through a wire. Place a zinc rod in zinc sulphate solution and a copper rod in copper sulphate solution. At each metal-solution interface, the oxidised and reduced forms of one substance are present together. Such a pair is called a redox couple, written oxidised form / reduced form: here Zn²⁺/Zn and Cu²⁺/Cu.

Join the two solutions with a salt bridge, a U-tube filled with a solution of an inert electrolyte such as KCl or NH₄NO₃, usually set in agar-agar jelly. It lets ions move between the beakers, completing the circuit, without letting the solutions mix. Join the rods by a wire through an ammeter and switch. This arrangement is the Daniell cell. When the switch is closed, zinc is oxidised (Zn → Zn²⁺ + 2e⁻), electrons travel through the wire to the copper rod, and Cu²⁺ ions are reduced there (Cu²⁺ + 2e⁻ → Cu). Conventional current flows in the opposite direction to the electrons, from copper to zinc in the wire.

The circuit in a Daniell cell

  1. Zinc electrode Zn → Zn²⁺ + 2e⁻ (oxidation, anode).
  2. External wire Electrons flow from the zinc rod to the copper rod.
  3. Copper electrode Cu²⁺ + 2e⁻ → Cu (reduction, cathode).
  4. Salt bridge Ions migrate between the solutions, keeping each electrically neutral and completing the circuit.

Then back to step 1: Zinc electrode

Standard electrode potentials

Current flows only because there is a potential difference between the two electrodes. The potential of each electrode is its electrode potential. When every species in the electrode reaction is at unit concentration (any gas at 1 atm in the textbook convention) and the temperature is 298 K, it is called the standard electrode potential, E°. By convention the hydrogen electrode, 2H⁺ + 2e⁻ → H₂, is given E° = 0.00 V. Values are listed as reduction potentials.

Selected standard electrode potentials (standard accepted values)
Couple (reduction)E° / V at 298 K
F₂ + 2e⁻ → 2F⁻+2.87
MnO₄⁻ + 8H⁺ + 5e⁻ → Mn²⁺ + 4H₂O+1.51
Cl₂ + 2e⁻ → 2Cl⁻+1.36
Br₂ + 2e⁻ → 2Br⁻+1.09
Ag⁺ + e⁻ → Ag+0.80
Fe³⁺ + e⁻ → Fe²⁺+0.77
I₂ + 2e⁻ → 2I⁻+0.54
Cu²⁺ + 2e⁻ → Cu+0.34
2H⁺ + 2e⁻ → H₂0.00
Fe²⁺ + 2e⁻ → Fe−0.44
Zn²⁺ + 2e⁻ → Zn−0.76
Mg²⁺ + 2e⁻ → Mg−2.36
Li⁺ + e⁻ → Li−3.05

Reading the table: the higher (more positive) E°, the more readily the oxidised form is reduced, so the stronger the oxidising agent (F₂ is the strongest here). The lower (more negative) E°, the more readily the reduced form gives up electrons, so the stronger the reducing agent (Li is the strongest here). A negative E° means the couple is a stronger reducing agent than H⁺/H₂; a positive E° means a weaker one.

The oxidised form of a couple with higher E° can oxidise the reduced form of any couple with lower E°.

Worked example 3: is the reaction feasible?

(a) Fe³⁺ with I⁻. E°(Fe³⁺/Fe²⁺) = +0.77 V is higher than E°(I₂/I⁻) = +0.54 V, so Fe³⁺ can oxidise I⁻: 2Fe³⁺ + 2I⁻ → 2Fe²⁺ + I₂. Feasible. (b) Fe³⁺ with Br⁻. +0.77 V is lower than E°(Br₂/Br⁻) = +1.09 V, so Fe³⁺ cannot oxidise Br⁻. Not feasible. (c) Cu with 1 M acid. E°(Cu²⁺/Cu) = +0.34 V is above 0.00 V, so H⁺ cannot oxidise Cu; copper does not release hydrogen. Zinc (−0.76 V) does. In Class 12 you will express this as E°cell = E°cathode − E°anode; for the Daniell cell this gives 0.34 − (−0.76) = 1.10 V.

Key takeaways

  • Redox titrations use permanganate as its own indicator, diphenylamine with dichromate, or starch in iodine-thiosulphate titrations.
  • Titration calculations use the mole ratio from the balanced redox equation.
  • A redox couple is the oxidised and reduced forms of one substance, e.g. Cu²⁺/Cu; the Daniell cell joins Zn²⁺/Zn and Cu²⁺/Cu through a wire and a salt bridge.
  • Standard electrode potentials are measured against the hydrogen electrode (0.00 V) at 298 K and unit concentration.
  • Higher E° means a stronger oxidant; lower E° means a stronger reductant.

Check your understanding

  1. 1. Why is no separate indicator needed when KMnO₄ is titrated against Fe²⁺ in acid?

    1. MnO₄⁻ is intensely coloured and its first lasting excess turns the solution pink
    2. Fe²⁺ turns blue at the end point
    3. The solution boils at the end point
    4. Mn²⁺ ions are deep purple
    Show answer

    Answer: A. Permanganate is purple and is decolourised as long as Fe²⁺ remains. A very small excess after the equivalence point gives a lasting pink colour, so MnO₄⁻ acts as its own indicator. Mn²⁺ is almost colourless.

  2. 2. What volume of 0.020 mol L⁻¹ KMnO₄ is needed to oxidise 10.0 mL of 0.10 mol L⁻¹ Fe²⁺ in acidic solution?

    1. 5.0 mL
    2. 25.0 mL
    3. 50.0 mL
    4. 10.0 mL
    Show answer

    Answer: D. Moles of Fe²⁺ = 0.10 × 0.0100 = 1.0 × 10⁻³ mol. MnO₄⁻ : Fe²⁺ = 1 : 5, so moles of MnO₄⁻ = 2.0 × 10⁻⁴ mol. Volume = 2.0 × 10⁻⁴ ÷ 0.020 = 0.010 L = 10.0 mL.

  3. 3. Using the standard electrode potentials Zn²⁺/Zn −0.76 V, Fe²⁺/Fe −0.44 V, Cu²⁺/Cu +0.34 V and Ag⁺/Ag +0.80 V, which metal is the strongest reducing agent?

    1. Ag
    2. Cu
    3. Zn
    4. Fe
    Show answer

    Answer: C. The most negative reduction potential belongs to the couple whose metal most readily loses electrons. Zn (−0.76 V) is the lowest, so zinc is the strongest reducing agent of the four; silver is the weakest.

  4. 4. In a Daniell cell, in which direction do electrons flow in the external wire?

    1. From the copper rod to the zinc rod
    2. From the zinc rod to the copper rod
    3. Through the salt bridge from zinc to copper
    4. Electrons do not flow; only ions move
    Show answer

    Answer: B. Zinc is oxidised (Zn → Zn²⁺ + 2e⁻), and these electrons travel through the wire to the copper rod, where Cu²⁺ is reduced. Inside the cell, ions (not electrons) move through the salt bridge. Conventional current flows the opposite way, copper to zinc.

  5. 5. Assertion (A): Fe³⁺ ions can oxidise I⁻ ions to I₂ under standard conditions.
    Reason (R): The standard electrode potential of Fe³⁺/Fe²⁺ (+0.77 V) is higher than that of I₂/I⁻ (+0.54 V).

    1. Both A and R are true, and R is the correct explanation of A
    2. Both A and R are true, but R is not the correct explanation of A
    3. A is true, but R is false
    4. A is false, but R is true
    Show answer

    Answer: A. The oxidised form of the couple with the higher E° (Fe³⁺) can oxidise the reduced form of the couple with the lower E° (I⁻): 2Fe³⁺ + 2I⁻ → 2Fe²⁺ + I₂. Both statements are true and R explains A.

Sign in to keep track of the lessons you finish.