- Foundation
- About 22 min
- 5 practice questions
Purifying organic compounds and detecting their elements: distillation, chromatography and Lassaigne's test
Choose between sublimation, crystallisation, the kinds of distillation, differential extraction and chromatography, calculate Rf values, and detect carbon, hydrogen, nitrogen, sulphur, halogens and phosphorus.
If something looks wrong, please tell us.
By the end of this lesson you can
- Pick a purification method from the nature of the compound and its impurity.
- Explain simple, fractional, reduced-pressure and steam distillation, and solve a steam distillation pressure problem.
- Describe adsorption and partition chromatography and calculate Rf values.
- Detect C and H with copper(II) oxide, and N, S, halogens and P with Lassaigne's test and related tests, writing the reactions.
A compound taken from a plant or made in the laboratory is almost never pure. The method used to purify it depends on the compound and the impurity. Purity is then checked: most pure compounds have a sharp melting or boiling point, and modern checks use chromatographic and spectroscopic techniques.
Sublimation and crystallisation
Sublimation separates a solid that turns directly to vapour on heating, such as naphthalene or camphor, from an impurity that does not sublime, such as sand or common salt; the vapour is cooled back to solid away from the residue. Crystallisation is the commonest way to purify solids. Choose a solvent in which the compound is only sparingly soluble when cold but quite soluble when hot. Dissolve the impure solid in the hot solvent, make a nearly saturated solution, filter, and cool: pure crystals separate and are filtered off, leaving most impurities in the mother liquor. If no single solvent works, a mixture of a 'good' and a 'poor' solvent may. Coloured impurities are removed by adsorbing them on activated charcoal, and impurities with similar solubility need repeated crystallisation.
Distillation and its variants
Simple distillation separates a volatile liquid from non-volatile impurities, or two liquids whose boiling points are far apart (for example diethyl ether, about 308 K, from toluene, about 384 K). The lower-boiling liquid vaporises first, is condensed and collected; the other follows later. Fractional distillation is used when boiling points are close. The vapour passes up a fractionating column, whose many surfaces let rising vapour and falling liquid exchange heat repeatedly; each evaporation-condensation unit is a theoretical plate. The vapour reaching the top is rich in the more volatile liquid, while the flask becomes richer in the less volatile one. Crude oil is separated into fractions this way.
Distillation under reduced pressure purifies liquids with very high boiling points or that decompose at or below their boiling points. A liquid boils when its vapour pressure equals the external pressure, so lowering the pressure with a water pump or vacuum pump lowers the boiling temperature. Glycerol is recovered from spent lye in soap-making this way. Steam distillation is for compounds that are volatile in steam and immiscible with water, such as aniline. Steam is blown through the heated mixture; it boils when the vapour pressure of the organic liquid (p₁) plus that of water (p₂) equals the external pressure p. Because p₁ alone is less than p, the compound distils below its own boiling point, and the mixture boils close to, but below, 373 K. The condensed compound is then separated from the water in a separating funnel.
Steam distillation: the mixture boils when p = p₁ + p₂, so each liquid needs to supply only part of the external pressure.
Worked example 1: pressure share in steam distillation
A water-immiscible liquid is steam distilled at 760 mm Hg. At the temperature where the mixture boils, take the vapour pressure of water as 707 mm Hg (its value near 371 K). Then p₁ = p − p₂ = 760 − 707 = 53 mm Hg. The organic liquid needs a vapour pressure of only 53 mm Hg, which it reaches far below its normal boiling point, so it distils with the steam at about 371 K.
Differential extraction
An organic compound dissolved in water is shaken with an organic solvent that does not mix with water and dissolves the compound better than water does. The two layers separate in a separating funnel, the organic layer is run off, and the solvent is removed by distillation or evaporation. If the compound is only slightly more soluble in the organic solvent, continuous extraction reuses the same solvent many times.
Chromatography
Chromatography (Greek chroma, colour, because it was first used on plant pigments) separates mixtures, purifies compounds and tests purity. The mixture is placed on a stationary phase (solid or liquid) and a mobile phase (a solvent, solvent mixture or gas) moves slowly over it, carrying the components different distances. In adsorption chromatography components are held to different extents on an adsorbent such as silica gel or alumina. In column chromatography the adsorbent is packed in a glass tube with a stopcock and an eluant flows down; the most strongly adsorbed substance stays near the top. In thin layer chromatography (TLC) a layer about 0.2 mm thick of adsorbent on a glass plate (the chromaplate) is spotted about 2 cm from one end and stood in a closed jar of eluant. In partition chromatography components distribute continuously between two phases; in paper chromatography water held in the paper is the stationary phase and a solvent rising by capillary action is the mobile phase, giving a chromatogram. Colourless spots are seen under ultraviolet light, in a jar of iodine crystals (brown spots), or by spraying a reagent, for example ninhydrin for amino acids.
Retardation factor: Rf = distance moved by the substance from the base line ÷ distance moved by the solvent front from the base line. Rf has no unit and is less than 1.
Worked example 2: Rf values on a TLC plate
The solvent front moves 9.0 cm from the base line. Spot A moves 3.6 cm and spot B 7.2 cm. Rf(A) = 3.6 ÷ 9.0 = 0.40 and Rf(B) = 7.2 ÷ 9.0 = 0.80. A is held more strongly by the adsorbent; B is adsorbed less and travels further with the solvent. Spot B would leave a column first.
| Method | Principle | Typical use |
|---|---|---|
| Sublimation | Solid passes directly to vapour | Naphthalene from sand |
| Crystallisation | Different solubility, hot and cold | Purifying most organic solids |
| Simple distillation | Boiling points far apart | Volatile liquid from non-volatile impurity |
| Fractional distillation | Close boiling points, many vaporisation-condensation steps | Crude oil fractions |
| Reduced-pressure distillation | Boiling point falls when pressure falls | Glycerol from spent lye |
| Steam distillation | p = p₁ + p₂; boils below 373 K | Aniline from its mixture with water |
| Differential extraction | Greater solubility in an immiscible solvent | Organic compound from water |
| Chromatography | Different adsorption or partition between phases | Separating and testing mixtures |
Detecting the elements
Carbon and hydrogen. Heat the compound with copper(II) oxide. Carbon is oxidised to CO₂, which turns lime-water milky: C + 2CuO → 2Cu + CO₂, then Ca(OH)₂ + CO₂ → CaCO₃ + H₂O. Hydrogen becomes water, which turns white anhydrous copper sulphate blue: 2H + CuO → Cu + H₂O, then CuSO₄ + 5H₂O → CuSO₄·5H₂O.
Lassaigne's test for N, S, halogens and P. The covalently bound elements are first turned into ions by fusing the compound with sodium: Na + C + N → NaCN; 2Na + S → Na₂S; Na + X → NaX (X = Cl, Br, I). The fused mass is boiled with distilled water to give the sodium fusion extract.
| Element | Test on the sodium fusion extract | Positive result and reaction |
|---|---|---|
| Nitrogen | Boil with iron(II) sulphate, then acidify with concentrated sulphuric acid | Prussian blue: 6CN⁻ + Fe²⁺ → [Fe(CN)₆]⁴⁻; some Fe²⁺ is oxidised to Fe³⁺ and 3[Fe(CN)₆]⁴⁻ + 4Fe³⁺ → Fe₄[Fe(CN)₆]₃·xH₂O |
| Sulphur (a) | Acidify with acetic acid, add lead acetate | Black precipitate: S²⁻ + Pb²⁺ → PbS |
| Sulphur (b) | Add sodium nitroprusside | Violet: S²⁻ + [Fe(CN)₅NO]²⁻ → [Fe(CN)₅NOS]⁴⁻ |
| N and S together | Fusion gives Na + C + N + S → NaSCN; add Fe³⁺ | Blood red [Fe(SCN)]²⁺ and no Prussian blue (no free CN⁻) |
| Halogens | Acidify with nitric acid, add silver nitrate | AgCl white, soluble in NH₄OH; AgBr pale yellow, sparingly soluble; AgI yellow, insoluble |
| Phosphorus | Heat compound with Na₂O₂ (phosphate forms), boil with HNO₃, add ammonium molybdate | Yellow ammonium phosphomolybdate, (NH₄)₃PO₄·12MoO₃ |
Two practical points. With excess sodium, thiocyanate breaks up (NaSCN + 2Na → NaCN + Na₂S), so the separate tests for N and S work again. When N or S is present, the extract is boiled with concentrated nitric acid before the halogen test to destroy CN⁻ and S²⁻, which would otherwise react with Ag⁺ and spoil the result.
Worked example 3: reading test results
A compound's sodium fusion extract gives no Prussian blue but turns blood red with iron(III) chloride. After boiling with concentrated HNO₃ and adding AgNO₃, a yellow precipitate forms that does not dissolve in ammonia. Reasoning: blood red with Fe³⁺ means SCN⁻, so the compound contains both N and S (fusion was not done with excess sodium); a yellow precipitate insoluble in NH₄OH is AgI, so iodine is present.
Key takeaways
- Crystallisation suits solids; the kind of distillation depends on boiling points, stability and miscibility with water.
- Steam distillation works because p = p₁ + p₂, so the compound boils below 373 K.
- Rf = distance by substance ÷ distance by solvent; the more strongly adsorbed component has the lower Rf.
- Sodium fusion turns covalent N, S and X into NaCN, Na₂S and NaX; nitrogen gives Prussian blue, N + S together give blood red.
Check your understanding
-
1. On a paper chromatogram, the solvent front is 8.0 cm from the base line and a spot is 2.4 cm from it. What is the Rf value of the spot?
- 3.33
- 0.30
- 0.24
- 0.70
Show answer
Answer: B. Rf = distance moved by the substance ÷ distance moved by the solvent = 2.4 ÷ 8.0 = 0.30. An Rf can never exceed 1, so 3.33 (the ratio inverted) is impossible.
-
2. Which technique is used to recover glycerol from spent lye in the soap industry?
- Steam distillation
- Sublimation
- Distillation under reduced pressure
- Fractional crystallisation
Show answer
Answer: C. Glycerol has a very high boiling point and decomposes near it, so it is distilled at lower pressure, where it boils at a lower temperature.
-
3. In Lassaigne's test, the sodium fusion extract gives a blood-red colour with iron(III) chloride. What does this show?
- Only nitrogen is present
- Only sulphur is present
- A halogen is present
- Both nitrogen and sulphur are present
Show answer
Answer: D. Blood red is [Fe(SCN)]²⁺, formed from thiocyanate. NaSCN forms only when both N and S are in the compound.
-
4. Assertion (A): When nitrogen or sulphur is present, the sodium fusion extract is boiled with concentrated nitric acid before the silver nitrate test for halogens. Reason (R): Nitric acid converts halide ions into silver halides.
- Both A and R are true, and R is the correct explanation of A.
- Both A and R are true, but R is not the correct explanation of A.
- A is true, but R is false.
- A is false, but R is true.
Show answer
Answer: C. A is true: boiling with HNO₃ drives off CN⁻ and S²⁻ (as HCN and H₂S), which would otherwise react with Ag⁺. R is false: silver halides form from silver nitrate, not from nitric acid.
-
5. A water-immiscible liquid is steam distilled at an external pressure of 760 mm Hg. At the boiling temperature, take the vapour pressure of water as 733 mm Hg. What is the vapour pressure of the organic liquid at that temperature?
- 27 mm Hg
- 733 mm Hg
- 760 mm Hg
- 1493 mm Hg
Show answer
Answer: A. The mixture boils when p₁ + p₂ = p, so p₁ = 760 − 733 = 27 mm Hg.
Sign in to keep track of the lessons you finish.