Electric charge, current and the electric circuit

Electric current I = Q ÷ t, where Q is the net charge (in coulomb) flowing in time t (in seconds). 1 ampere = 1 coulomb per second.

Two directions to remember

  • Conventional current
    • From the positive terminal to the negative terminal outside the cell
    • Used in all circuit diagrams and rules
  • Electron flow
    • From the negative terminal to the positive terminal
    • Opposite to the conventional current

A simple closed circuit

  1. Cell Provides the push on the charges.
  2. Plug key (switch) Closes or breaks the path.
  3. Ammeter Connected in series to measure current.
  4. Bulb Glows while current flows.
  5. Back to the cell The path must be complete for current to flow.

Key takeaways: current is the rate of flow of charge, I = Q ÷ t, measured in ampere (1 A = 1 C/s). One electron carries 1.6 × 10⁻¹⁹ C, so n = Q ÷ e. Current flows only in a closed circuit. Conventional current goes from + to − outside the cell, opposite to the electron flow. An ammeter is connected in series.

Read the full lesson

Lesson 2

Potential difference and circuit diagrams

Potential difference V = W ÷ Q: the work done to move a unit charge from one point to another. 1 volt = 1 joule per coulomb.

Ammeter and voltmeter

  • Ammeter
    • Measures current
    • Unit: ampere
    • Connected in series
    • Has very low resistance
  • Voltmeter
    • Measures potential difference
    • Unit: volt
    • Connected in parallel across a component
    • Has very high resistance
Common circuit symbols, described in words
ComponentHow its symbol is drawn
Electric cellA long thin line (positive terminal) and a short thick line (negative terminal), side by side
BatteryTwo or more cell symbols joined in a row
Plug key or switch (open)A gap in the line, or a key shown open
Plug key or switch (closed)The gap bridged
Wire jointTwo lines crossing with a solid dot at the join
Wires crossing without joiningOne line hopping over the other, with no dot
Electric bulbA circle with a cross or a small loop inside
ResistorA small rectangle (or zig-zag line)
Rheostat (variable resistance)A resistor symbol with an arrow across it
Ammeter / voltmeterA circle with A inside / a circle with V inside

Key takeaways: a potential difference is needed to make charges flow; a cell maintains one by chemical action. V = W ÷ Q, and 1 V = 1 J/C. A voltmeter is connected in parallel and an ammeter in series. Circuit diagrams use standard symbols to show connections clearly.

Read the full lesson

Lesson 3

Ohm's law, resistance and resistivity

Ohm's law: the potential difference across a conductor is directly proportional to the current through it, provided its temperature remains the same. V = I × R.

Factors affecting the resistance of a conductor

  • Length (l)
    • Directly proportional
    • Double the length, double the resistance
  • Area of cross-section (A)
    • Inversely proportional
    • A thicker wire has less resistance
  • Material
    • Measured by its resistivity ρ
    • Copper low, nichrome much higher
  • Temperature
    • For metals, resistance rises as temperature rises

R = ρ × l ÷ A, where ρ (rho) is the resistivity of the material, in ohm metre (Ω m).

Choosing a material
MaterialResistivityTypical use
Copper, aluminiumVery lowConnecting wires and power transmission lines
TungstenLow, but very high melting pointFilaments of electric bulbs
Alloys such as nichromeMuch higher than pure metals; do not oxidise (burn) readily when hotHeating elements of irons, toasters and heaters
Rubber, glass, plasticExtremely highInsulation

Key takeaways: Ohm's law says V = IR at constant temperature, and resistance is measured in ohm. The resistance of a wire is proportional to its length, inversely proportional to its area of cross-section, and depends on its material and temperature: R = ρl/A. Resistivity is a property of the material alone. Copper and aluminium carry current; alloys such as nichrome make heating elements.

Read the full lesson

Lesson 4

Resistors in series and in parallel

Series: Rs = R₁ + R₂ + R₃. Same current through each; voltages add up to the supply voltage.

Parallel: 1/Rp = 1/R₁ + 1/R₂ + 1/R₃. Same voltage across each; currents add up to the total current. Rp is less than the smallest resistance.

Series and parallel connections

  • Series
    • One path for the current
    • Same current in every resistor
    • Voltage is shared
    • Rs is larger than the largest resistor
    • If one device fails, the circuit breaks and all stop
  • Parallel
    • Separate path through each resistor
    • Same voltage across every resistor
    • Current is shared
    • Rp is smaller than the smallest resistor
    • Each device works and can be switched independently

Key takeaways: in series, Rs = R₁ + R₂ + R₃, the current is the same everywhere and the voltages add up. In parallel, 1/Rp = 1/R₁ + 1/R₂ + 1/R₃, the voltage is the same across each branch and the currents add up, and Rp is smaller than any single resistance. For combinations, simplify the parallel group first. Homes are wired in parallel.

Read the full lesson

Lesson 5

Heating effect of current and electric power

Joule's law of heating: H = I² × R × t. Heat produced is proportional to the square of the current, to the resistance and to the time.

Heat produced in a resistor (H = I²Rt)

  • Current I
    • Proportional to I²
    • Doubling the current gives four times the heat
  • Resistance R
    • Proportional to R for a given current
  • Time t
    • Proportional to the time for which current flows

Electric power P = V × I = I² × R = V² ÷ R. Energy = power × time; 1 kW h = 3.6 × 10⁶ J.

From appliance rating to bill

  1. Power in kW Watts ÷ 1000.
  2. Multiply by hours Energy per day in kW h.
  3. Multiply by days Total units used.
  4. Multiply by rate Cost in rupees.

Key takeaways: current through a resistance produces heat H = I²Rt, so doubling the current gives four times the heat. Heaters, bulbs and fuses use this effect; a fuse in series melts when the current exceeds its rating. Power P = VI = I²R = V²/R, measured in watt. Energy is sold in kilowatt hours, and 1 kW h = 3.6 × 10⁶ J.