Revision notes

Chapter 7 Alternating Current: Foundation

The key points, rules to remember, tables and diagrams from all 5 lessons, on one page for quick revision. To keep a copy, use your browser's Print and choose "Save as PDF".

Lesson 1

AC through a resistor, rms values and phasors

i = i_m sin ωt, with i_m = v_m/R. Ohm's law holds for ac in a resistor, and the current is in phase with the voltage: both reach zero, maximum and minimum at the same instants.

I = i_m/√2 ≈ 0.707 i_m and V = v_m/√2 ≈ 0.707 v_m. Then V = IR and P = I²R = V²/R = VI, exactly as for dc.

Reading a phasor diagram

  1. Draw each quantity as an arrow Length = amplitude; angle = phase at the chosen instant.
  2. Let the arrows rotate anticlockwise All at the same angular speed ω.
  3. Take vertical projections They give the instantaneous values v and i.
  4. Compare angles The arrow ahead (anticlockwise) leads; the one behind lags.
  • v = v_m sin ωt; in a resistor i = (v_m/R) sin ωt, in phase with v.
  • Average current over a cycle is zero, but average power is ½i_m²R.
  • rms values: I = i_m/√2, V = v_m/√2; then V = IR and P = VI = I²R.
  • Phasors are rotating arrows whose projections give instantaneous values.
Read the full lesson

Lesson 2

AC through an inductor and through a capacitor

Pure inductor: i = i_m sin (ωt − π/2), i_m = v_m/X_L, inductive reactance X_L = ωL = 2πνL (ohm). The current lags the voltage by π/2 (a quarter cycle).

Pure capacitor: i = i_m sin (ωt + π/2), i_m = v_m/X_C, capacitive reactance X_C = 1/(ωC) = 1/(2πνC) (ohm). The current leads the voltage by π/2.

The three circuit elements on ac
ElementOppositionPhase of currentEffect of raising νAverage power
Resistor RRIn phase with vNo changeI²R
Inductor LX_L = ωLLags v by π/2X_L rises, I fallsZero
Capacitor CX_C = 1/ωCLeads v by π/2X_C falls, I risesZero

Inductor and capacitor on ac

  • Inductor
    • X_L = ωL ∝ ν
    • Current lags voltage by 90°
    • Blocks high frequencies
    • Stores energy in its magnetic field
  • Capacitor
    • X_C = 1/ωC ∝ 1/ν
    • Current leads voltage by 90°
    • Blocks dc and low frequencies
    • Stores energy in its electric field
  • Inductor: X_L = ωL; current lags voltage by π/2.
  • Capacitor: X_C = 1/ωC; current leads voltage by π/2; dc is blocked.
  • Reactances are measured in ohms; X_L rises and X_C falls with frequency.
  • Pure L or C: average power over a cycle is zero.
Read the full lesson

Lesson 3

Series LCR circuit: impedance and phase

i_m = v_m/Z, with impedance Z = √[R² + (X_C − X_L)²] (ohm). Phase angle: tan φ = (X_C − X_L)/R.

Reading the phase angle
ConditionSign of φCircuit behaves asCurrent
X_C > X_LPositiveCapacitiveLeads the source voltage
X_L > X_CNegativeInductiveLags the source voltage
X_L = X_CZeroPurely resistive (Z = R)In phase with the voltage (resonance)

Solving a series LCR problem

  1. Reactances X_L = ωL and X_C = 1/ωC at the given frequency.
  2. Impedance Z = √[R² + (X_C − X_L)²].
  3. Current I = V/Z (rms) or i_m = v_m/Z (peak).
  4. Phase tan φ = (X_C − X_L)/R; decide lead or lag.
  5. Element voltages V_R = IR, V_L = IX_L, V_C = IX_C; combine by phasors.
  • Same current through all series elements; their voltages differ in phase.
  • Z = √[R² + (X_C − X_L)²]; i_m = v_m/Z.
  • tan φ = (X_C − X_L)/R: positive φ (capacitive) means current leads; negative (inductive) means it lags.
  • Element voltages add as phasors, not as numbers.
Read the full lesson

Lesson 4

Resonance and power in ac circuits

Resonance: X_L = X_C, i.e. ω₀L = 1/(ω₀C), so ω₀ = 1/√(LC) and ν₀ = 1/(2π√(LC)). At resonance Z = R, i_m = v_m/R and φ = 0.

P = (v_m i_m/2) cos φ = V I cos φ = I²Z cos φ. The factor cos φ is the power factor; for a series LCR circuit cos φ = R/Z.

Power in different ac circuits
CircuitφPower factorAverage power
Pure resistor01Maximum, VI
Pure L or pure C±π/20Zero (wattless current)
RL, RC or LCRBetweenR/ZI²R - dissipated only in R
LCR at resonance01Maximum, I²R with I = V/R

Improving a low power factor

  1. Inductive load Current lags the voltage; it has a large wattless component.
  2. Add a capacitor in parallel It draws a leading wattless current.
  3. Wattless parts cancel Only the power component, in phase with V, remains.
  4. Result cos φ → 1, smaller line current, smaller transmission loss.
  • Resonance: X_L = X_C, ω₀ = 1/√(LC); Z = R and current is maximum; needs both L and C.
  • Q = ω₀L/R measures sharpness; tuning a radio varies C to set ω₀.
  • P = VI cos φ; power factor cos φ = R/Z; only R dissipates power.
  • Wattless current: cos φ = 0; a low power factor raises transmission losses, and a parallel capacitor can improve it.
Read the full lesson

Lesson 5

Transformers

Ideal transformer: V_s/V_p = N_s/N_p and I_s/I_p = N_p/N_s (rms or peak values; the frequency is unchanged).

Step-up and step-down transformers

  • Step-up (N_s > N_p)
    • V_s > V_p
    • I_s < I_p
    • Used at power stations before transmission
  • Step-down (N_s < N_p)
    • V_s < V_p
    • I_s > I_p
    • Used at sub-stations and for chargers and appliances
Losses in a transformer
LossCauseHow it is reduced
Flux leakageSome primary flux does not pass through the secondary (poor core design, air gaps)Wind the primary and secondary one over the other
Resistance of windingsI²R heating in the wiresUse thick wire for high-current, low-voltage windings
Eddy currentsThe alternating flux induces circulating currents in the iron core, heating itUse a laminated core
HysteresisRepeated reversal of the core's magnetisation dissipates energy as heatUse a core material with low hysteresis loss

From power station to home

  1. Generator Produces ac at a moderate voltage.
  2. Step-up transformer Raises the voltage greatly; current falls.
  3. Transmission lines Long distance at high voltage, low current, small I²R loss.
  4. Step-down sub-stations Voltage lowered in stages.
  5. Home supply Delivered at a safe, usable voltage.
  • A transformer works by mutual induction through a shared iron core; it works only with ac.
  • Ideal: V_s/V_p = N_s/N_p, I_s/I_p = N_p/N_s, power in = power out.
  • Losses: flux leakage, winding resistance, eddy currents (laminated core), hysteresis.
  • Stepping up the voltage for transmission cuts the I²R loss by the square of the turns ratio.
Read the full lesson

Privacy · Terms · Refunds · Delivery