Biogas sums: dung and gas, dilution by solids, retention time and energy
Solve biogas plant problems by finding feed from a gas need, diluting dung with a solids balance, sizing the digester from retention time, and converting gas to useful energy.
If something looks wrong, please tell us.
Biogas questions mix a concept (decay without air) with four short calculations: how much feed gives the gas needed, how much water to add, how big the digester must be, and how much useful energy results. All values in this lesson are illustrative figures for practice, not design standards, and real plants vary with temperature and feed.
The four calculations
- Feed for a gas need: feed = gas needed ÷ yield per kg of feed.
- Dilution: fresh dung is mixed with water; the dry solids are the same before and after, so total feed mass = dung solids ÷ target solids fraction.
- Digester volume: volume = daily feed volume × retention time in days.
- Useful energy: gas volume × energy per cubic metre × burner efficiency.
Solids never change on dilution: dung mass × solids fraction = feed mass × target fraction. Volume = daily feed × retention days. 1 kWh = 3.6 MJ.
Worked example 1: feed and dilution
A household needs 2 m³ of biogas a day, and each kilogram of fresh dung gives 0.04 m³ (illustrative). Dung needed = 2 ÷ 0.04 = 50 kg a day. Fresh dung has about 20 per cent total solids, and the digester feed should have about 8 per cent. Dry solids in 50 kg of dung = 50 × 0.20 = 10 kg. Total feed mass = 10 ÷ 0.08 = 125 kg. Water to add = 125 − 50 = 75 kg. The trap is to work with the percentages by subtraction (20 − 8 = 12 per cent), or to assume the usual 1:1 dung-to-water mix when the question sets a different solids target; the solids balance is the reliable method.
Worked example 2: digester size and energy
The 125 kg of feed has about the density of water, 1,000 kg per m³, so the feed volume is 0.125 m³ a day. With a retention time of 40 days, digester volume = 0.125 × 40 = 5 m³. Note that the feed volume, not the dung mass alone, is used. Now the energy: at an illustrative 22 MJ per m³, 2 m³ of gas holds 2 × 22 = 44 MJ. A burner that is 55 per cent efficient delivers 44 × 0.55 = 24.2 MJ of useful heat a day. In kWh, 24.2 ÷ 3.6 ≈ 6.7 kWh of heat. Over a 30-day month the useful heat is about 726 MJ.
Why retention time matters
Hydraulic retention time is the average time the feed stays in the digester. If it is too short, microbes are washed out before they finish the work, and gas yield drops. If it is too long, the digester is bigger and costlier than it needs to be. In cold weather microbes work slowly, so a longer retention time or a warmer digester is needed. For this reason, gas production in winter is lower than in summer for the same feed.
Common traps
- Using the dung mass as the feed volume: the added water must be included.
- Dividing by the burner efficiency when multiplying is needed: useful energy is smaller than gas energy.
- Calling the digestate waste: it is a manure with most of the nutrients retained.
- Mixing aerobic and anaerobic: composting needs air; biogas production needs none.
- Confusing the gas (mostly methane with carbon dioxide) with the slurry.
Key takeaways
Feed equals gas need divided by yield. Dilute using a solids balance. Digester volume is daily feed volume times retention time. Useful energy is gas energy times burner efficiency. A cold digester produces less gas.
Check your understanding
-
1. A household needs 3 m³ of biogas a day and each kilogram of dung gives 0.04 m³. How much dung is needed daily?
- 120 kg
- 75 kg
- 7.5 kg
- 0.12 kg
Show answer
Answer: B. Dung = 3 ÷ 0.04 = 75 kg a day.
-
2. A digester receives 0.2 m³ of feed a day with a retention time of 40 days. What volume is needed?
- 200 m³
- 0.005 m³
- 40 m³
- 8 m³
Show answer
Answer: D. Volume = 0.2 × 40 = 8 m³.
-
3. 40 kg of dung with 20 per cent solids is diluted to a feed of 8 per cent solids. How much water must be added?
- 60 kg
- 100 kg
- 40 kg
- 8 kg
Show answer
Answer: A. Solids = 40 × 0.20 = 8 kg. Total feed = 8 ÷ 0.08 = 100 kg. Water = 100 − 40 = 60 kg.
-
4. 3 m³ of biogas at 22 MJ per m³ is burned in a burner of 50 per cent efficiency. What useful heat results?
- 66 MJ
- 132 MJ
- 33 MJ
- 14.5 MJ
Show answer
Answer: C. Gas energy = 3 × 22 = 66 MJ. Useful heat = 66 × 0.50 = 33 MJ.
-
5. Why does a biogas plant give less gas in cold weather?
- Methane cannot be made below a fixed height
- Cold weather adds oxygen to the digester
- Dung loses its solids when it is cold
- Microbes work more slowly, so less gas is made
Show answer
Answer: D. Anaerobic microbes are slower at low temperatures, so gas output falls unless the retention time is lengthened or the digester is kept warm.