• Foundation
  • About 14 min
  • 5 practice questions

Alternating current, transmission and safety in home wiring

Understand peak and r.m.s. values, why power is sent at high voltage, and how fuses and earthing protect people and appliances.

If something looks wrong, please tell us.

The electricity that reaches a home is alternating current, made by generators and carried by wires and transformers. This lesson ties together the ideas of generators and transformers with everyday practice: how to describe AC, why power is sent at high voltage and how a house is protected from faults.

Describing alternating current

An AC supply varies like a sine wave, rising to a peak value V₀, falling to zero, reversing and so on. Its frequency f is the number of complete cycles per second (hertz) and the time period is T = 1/f. The value that matters for heating is the r.m.s. (root mean square) value: V_rms = V₀/√2 ≈ 0.707 V₀. A supply called '220 V' refers to the r.m.s. value, so its peak is about 220 × 1.414 ≈ 311 V. Meters and bulbs are labelled in r.m.s. values. Direct current (DC) from a cell or battery does not reverse.

Why power is sent at high voltage

The power sent along a line is P = VI. The line has resistance R, and the power wasted as heat in it is I²R. For a given P, raising V lowers I, and the loss falls with the square of the current. Transformers raise the voltage at the power station and lower it again near homes.

Worked example 1: line loss

The numbers are illustrative. A power of 22 kW = 22 000 W is sent along a line of total resistance 0.5 Ω. At 220 V the current is 22 000/220 = 100 A and the loss is I²R = 100² × 0.5 = 5000 W. If a transformer raises the voltage to 2200 V, the current is 22 000/2200 = 10 A and the loss is 10² × 0.5 = 50 W. A ten-fold rise in voltage cuts the loss by a factor of 100.

Home wiring and safety

  • A house circuit has three wires: live, neutral and earth. The live wire carries the supply potential; the neutral completes the circuit.
  • The fuse or circuit breaker is placed in the live wire. A fuse is a thin wire that melts if the current becomes too large, cutting off the supply. Its rating should be a little above the normal current of the circuit.
  • The earth wire connects the metal body of an appliance to the ground. If the live wire touches the body by mistake, the large current flows to earth and blows the fuse, instead of giving a shock to the user.
  • Overloading (too many appliances on one circuit) and a short circuit (live and neutral touching) both cause a large current and a fire risk.

Worked example 2: choosing a fuse and finding energy

An electric iron is rated 2.2 kW on a 220 V supply. Its normal current is I = P/V = 2200/220 = 10 A, so the fuse must have a rating a little above 10 A. If a 2 kW heater runs for 3 hours, the energy used is 2 kW × 3 h = 6 kWh (units). One kilowatt-hour is 3.6 × 10⁶ J, so 6 kWh = 2.16 × 10⁷ J.

V_rms = V₀/√2. Loss in line = I²R. Fuse and switch go in the live wire; earth wire is connected to the metal body. 1 kWh = 3.6 × 10⁶ J.

— Rules to remember

Key takeaways

Quote AC in r.m.s. values, send power at high voltage to cut I²R loss, and protect every circuit with a fuse in the live wire and an earth connection to the metal body.

Check your understanding

  1. 1. An AC supply of 220 V r.m.s. has a peak voltage of about:

    1. 155 V
    2. 380 V
    3. 311 V
    4. 220 V
    Show answer

    Answer: C. V₀ = V_rms × √2 = 220 × 1.414 ≈ 311 V.

  2. 2. In a line of resistance R, doubling the current makes the power loss:

    1. half
    2. twice
    3. unchanged
    4. four times
    Show answer

    Answer: D. Power loss is I²R, so doubling I makes the loss four times as large.

  3. 3. A fuse should be connected in:

    1. the live wire
    2. the earth wire
    3. the neutral wire
    4. a separate loop
    Show answer

    Answer: A. The fuse (and the switch) are placed in the live wire so that the appliance is cut off from the supply when the fuse blows.

  4. 4. A 1100 W appliance runs on a 220 V supply. The normal current is:

    1. 0.2 A
    2. 5 A
    3. 10 A
    4. 242 A
    Show answer

    Answer: B. I = P/V = 1100/220 = 5 A.

  5. 5. The energy used by a 500 W appliance in 4 hours is:

    1. 2 kWh
    2. 4 kWh
    3. 125 kWh
    4. 0.5 kWh
    Show answer

    Answer: A. E = 0.5 kW × 4 h = 2 kWh.

Sign in to keep track of the lessons you finish.

Next lesson → Final self-assessment: Magnetism