Revision notes

Unit 4 Electromagnetic Induction And Alternating Current: Foundation

The key points, rules to remember, tables and diagrams from all 5 lessons, on one page for quick revision. To keep a copy, use your browser's Print and choose "Save as PDF".

Lesson 1

Magnetic flux, Faraday's laws, Lenz's law and motional emf

Using Lenz's law to find the current direction

  1. Identify the flux Which way does the existing field point through the loop?
  2. Is it rising or falling? Approach, growing current or growing area means rising flux.
  3. Choose the induced field Opposite to the existing field if flux rises; along it if flux falls.
  4. Apply the right hand thumb rule The induced field direction gives clockwise or anticlockwise current.

Φ_B = BA cos θ; ε = −d(NΦ_B)/dt; motional emf ε = Blv; rod rotating about one end: ε = ½Bωl².

  • Flux Φ_B = BA cos θ, with θ measured from the normal; unit weber (T m²).
  • An emf is induced only while the flux linked with a circuit is changing: ε = −d(NΦ_B)/dt.
  • Lenz's law: the induced current opposes its cause; it follows from conservation of energy.
  • Fleming's right hand rule: forefinger field, thumb motion, middle finger current.
  • A conductor moving across a field has motional emf Blv; a rod rotating about one end has ½Bωl².
Read the full lesson

Lesson 2

Eddy currents, self-induction and mutual induction

Uses of eddy currents

  • Induction stove A coil under the cooking zone carries high-frequency AC; eddy currents in a suitable metal pan heat it by Joule heating.
  • Eddy current brake Electromagnets near the rails (linear brake) or a disc on the wheel shaft spinning between magnet poles (circular brake); the eddy currents oppose the motion. Used in high-speed trains and roller coasters.
  • Eddy current testing A coil carrying AC induces eddy currents in a test surface; a crack or air bubble changes their phase and amplitude, revealing the defect without damaging the object.
  • Electromagnetic damping The galvanometer coil is wound on a soft iron cylinder; eddy currents in it stop the coil swinging so it settles quickly to a steady reading.

ε = −L di/dt; L = μ₀μ_r n²Al; U_B = ½Li²; u_B = B²/2μ₀; M = μ₀μ_r n₁n₂A₂l.

  • Eddy currents whirl inside bulk metal when flux changes; they cause heating loss, cut by insulated laminations.
  • They are useful in induction stoves, eddy current brakes, non-destructive testing and galvanometer damping.
  • Self-induced emf ε = −L di/dt; L = μ₀μ_r n²Al for a long solenoid; inductance is electrical inertia.
  • An inductor stores U = ½Li²; the field's energy density is B²/2μ₀.
  • Mutual inductance M = μ₀μ_r n₁n₂A₂l uses the area of the smaller solenoid, and M₁₂ = M₂₁.
Read the full lesson

Lesson 3

Producing induced emf, AC generators and transformers

Three ways to change the flux Φ_B = BA cos θ

  • Change B
    • Relative motion of magnet and coil
    • Changing current in a nearby coil
  • Change A
    • Rod sliding on a fixed frame
    • Motional emf ε = Blv
  • Change θ
    • Rotate a coil in a field
    • Or rotate the field inside a fixed coil
    • Gives alternating emf

ε = ε_m sin ωt, with ε_m = NBAω = NBA(2πf). Zero when the coil's plane is perpendicular to B; maximum when it is parallel to B.

Energy losses in a transformer and how each is reduced
LossCauseReduced by
Hysteresis loss (core loss)Core is magnetised and demagnetised every cycleSteel of high silicon content
Eddy current loss (core loss)Alternating flux induces eddy currents in the coreVery thin laminations
Copper lossJoule heating i²R in the windingsWires of larger diameter
Flux leakageNot all primary flux links the secondaryWinding the coils one over the other
  • Induced emf can be produced by changing B, A or θ; for a sliding rod the mechanical power equals the heat produced.
  • A coil rotating in a field gives ε = NBAω sin ωt, maximum when its plane is parallel to B.
  • Large alternators have a stationary armature (stator) and a rotating DC-fed field (rotor); three-phase emfs are 120° apart.
  • Transformer: V_s/V_p = N_s/N_p = I_p/I_s; losses are hysteresis, eddy current, copper and flux leakage.
  • High-voltage transmission lowers the current and so the I²R loss.
Read the full lesson

Lesson 4

Alternating current: mean and RMS values, phasors and AC circuits

I_av = 2I_m/π = 0.637 I_m (half cycle); I_RMS = I_m/√2 = 0.707 I_m; X_L = ωL; X_C = 1/ωC; Z = √(R² + (X_L − X_C)²); tan φ = (X_L − X_C)/R.

Three pure AC circuits

  • Pure R
    • Opposition: R
    • i in phase with v
    • Power factor 1
  • Pure L
    • Opposition: X_L = ωL, grows with f
    • i lags v by 90°
    • Power factor 0
  • Pure C
    • Opposition: X_C = 1/ωC, falls with f
    • i leads v by 90°
    • Power factor 0
  • Mean value over a half cycle 0.637 I_m; RMS value 0.707 I_m; ratings like 230 V are RMS.
  • A phasor's length is the peak value and its vertical projection the instantaneous value.
  • R: in phase. L: current lags by 90°, X_L = ωL. C: current leads by 90°, X_C = 1/ωC.
  • Series RLC: Z = √(R² + (X_L − X_C)²), tan φ = (X_L − X_C)/R.
  • Resonance at f_r = 1/(2π√LC) where Z = R; Q = (1/R)√(L/C) is the voltage magnification.
Read the full lesson

Lesson 5

Power in AC circuits and LC oscillations

Phase and power factor in AC circuits (summary as in the textbook)
CircuitOppositionPhase of current with voltagePower factorAverage power
Pure RR0°1V_RMS I_RMS
Pure LX_L = ωLlags by 90°00
Pure CX_C = 1/ωCleads by 90°00
Series RLC√(R² + (ωL − 1/ωC)²)between 0° and 90°, lag or leadbetween 0 and 1V_RMS I_RMS cos φ
RLC at resonanceR0°1V_RMS I_RMS

AC versus DC (as listed in the textbook)

  • Advantages of AC
    • Cheaper to generate
    • Lower losses when transmitted at high voltage
    • Easily converted to DC by rectifiers
  • Disadvantages of AC
    • Cannot be used for charging batteries, electroplating, electric traction and similar uses
    • At high voltages it is more dangerous to work with than DC

One cycle of LC oscillation

  1. Capacitor fully charged q = Q_m, i = 0: energy Q_m²/2C, wholly electrical.
  2. Capacitor discharges Current grows in the inductor; energy is shared between the two fields.
  3. Capacitor empty, current maximum q = 0, i = I_m: energy ½LI_m², wholly magnetic. The inductor keeps the current flowing.
  4. Capacitor charges the opposite way The collapsing magnetic field drives the current on with falling size.
  5. Fully charged, reversed i = 0, wholly electrical again; then the whole process repeats with the current in the opposite direction.

Then back to step 1: Capacitor fully charged

Electrical and mechanical analogues
LC circuitSpring-mass system
Charge qDisplacement x
Current i = dq/dtVelocity v = dx/dt
Inductance LMass m
Reciprocal of capacitance 1/CForce constant k
Electrical energy q²/2CPotential energy ½kx²
Magnetic energy ½Li²Kinetic energy ½mv²

P_av = V_RMS I_RMS cos φ; power factor = cos φ = R/Z; LC oscillations: ω = 1/√(LC), total energy Q_m²/2C = ½LI_m², I_m = ωQ_m.

  • True power P_av = V_RMS I_RMS cos φ; apparent power V_RMS I_RMS; power factor cos φ = R/Z.
  • The component I_RMS sin φ is wattless; a pure L or pure C circuit consumes no average power.
  • Power factor is 1 for pure R and at resonance, 0 for pure L or C, and between 0 and 1 otherwise.
  • In LC oscillations energy passes between capacitor and inductor; the total stays Q_m²/2C.
  • L is like mass and 1/C like the spring constant, so ω = 1/√(LC).
Read the full lesson