• Practice
  • About 16 min
  • 5 practice questions

The Vernier caliper: least count, zero error and correct reading

Describe the parts of a Vernier caliper, find its least count, recognise positive and negative zero error and calculate the correct reading of a length.

If something looks wrong, please tell us.

By the end of this lesson you can

  • Explain what least count means for any measuring instrument.
  • Name the parts of a Vernier caliper and what each jaw measures.
  • Calculate the least count of a Vernier caliper.
  • Find positive and negative zero error and the zero correction.
  • Work out the correct reading of an object's length.

A metre scale is marked in centimetres and millimetres. The least count of an instrument is the smallest length it can measure correctly, and for an ordinary scale it is 1 mm. That is not fine enough for the diameter of a pen cap or a marble. A Vernier caliper measures to 0.1 mm (0.01 cm), and a screw gauge (next lesson) to 0.01 mm.

Parts of a Vernier caliper

  • Main scale: a long steel bar marked in cm and mm.
  • Fixed jaws: an upper and a lower jaw fixed at the left end of the main scale.
  • Slider with movable jaws: slides along the main scale and can be locked with a screw. It carries the Vernier scale.
  • Lower (outside) jaws: grip an object to measure outer sizes, such as the diameter of a ball.
  • Upper (inside) jaws: fit inside a hollow object to measure inner sizes, such as the inner diameter of a cup.
  • Depth bar: a thin rod at the right end that measures the depth of hollow objects.

Least count

Least count (L.C.) = value of one main scale division ÷ total number of Vernier scale divisions. On a common caliper the smallest main scale division is 1 mm and the Vernier scale has 10 divisions, so L.C. = 1 mm ÷ 10 = 0.1 mm = 0.01 cm.

Taking a reading

Place the object between the jaws. The main scale reading (MSR) is the main scale mark just to the left of the Vernier zero. Then look along the Vernier scale for the one division that lines up exactly with some main scale mark; its number is the Vernier scale coincidence (VSC). The observed reading is MSR + (VSC × L.C.).

Zero error and zero correction

Close the jaws so they touch. If the zero of the Vernier scale lines up with the zero of the main scale, there is no zero error. If not, the instrument has a zero error, which is added to every reading and must be removed.

Positive and negative zero error (Vernier caliper)

  • Positive zero error
    • Vernier zero is to the RIGHT of main scale zero
    • Readings come out too large
    • Error = + (coinciding division × L.C.)
    • Zero correction is negative
  • Negative zero error
    • Vernier zero is to the LEFT of main scale zero
    • Readings come out too small
    • Count the coinciding division backward from 10
    • Error = − (10 − n) × L.C.; correction is positive

The zero correction is the zero error with its sign reversed. Then: correct reading = MSR + (VSC × L.C.) + zero correction. Equivalently, subtract a positive zero error and add the size of a negative one.

Worked example 1: positive zero error

Question: With the jaws closed, the Vernier zero sits to the right of the main scale zero and the 3rd Vernier division coincides. Measuring a bottle cap gives MSR = 3.2 cm and VSC = 7. L.C. = 0.01 cm. Find the correct diameter. Working: Zero error = +3 × 0.01 = +0.03 cm, so zero correction = −0.03 cm. Observed reading = 3.2 + (7 × 0.01) = 3.27 cm. Correct reading = 3.27 − 0.03 = 3.24 cm.

Worked example 2: negative zero error

Question: With the jaws closed, the Vernier zero is to the left of the main scale zero and the 7th Vernier division coincides. A marble then gives MSR = 1.5 cm and VSC = 2. Find the correct diameter. Working: For a negative error count backward from 10: 10 − 7 = 3, so zero error = −3 × 0.01 = −0.03 cm and zero correction = +0.03 cm. Observed reading = 1.5 + (2 × 0.01) = 1.52 cm. Correct reading = 1.52 + 0.03 = 1.55 cm.

Worked example 3: radius of a ball

Question: A caliper with no zero error gives MSR = 5 cm and VSC = 4 for a rubber ball. Find its radius. Working: Diameter = 5 + (4 × 0.01) = 5.04 cm. Radius = 5.04 ÷ 2 = 2.52 cm.

Digital Vernier caliper

A digital Vernier caliper has an electronic display on the slider. It shows the measured length directly, so the user need not work out the least count, the coincidence or the zero error by hand. Pressing a zero button with the jaws closed sets the display to zero before measuring.

L.C. = one main scale division ÷ number of Vernier divisions = 0.01 cm. Correct reading = MSR + (VSC × L.C.) + zero correction, where zero correction = − zero error.

Key takeaways: the least count is the smallest length an instrument can measure. A Vernier caliper reads to 0.01 cm; its lower jaws measure outside sizes, its upper jaws inside sizes and its depth bar depths. Always check zero error with the jaws closed, then reverse its sign to get the zero correction.

Check your understanding

  1. 1. Which part of a Vernier caliper would you use to measure the inner diameter of a steel tumbler?

    1. The lower jaws
    2. The depth bar
    3. The upper jaws
    4. The locking screw
    Show answer

    Answer: C. The upper (inside) jaws are placed inside a hollow object and opened out to touch its inner wall, so they measure inner diameters. The lower jaws grip outer sizes and the depth bar measures depth.

  2. 2. A Vernier caliper has a smallest main scale division of 1 mm and 20 Vernier divisions. What is its least count?

    1. 0.1 mm
    2. 0.05 mm
    3. 0.2 mm
    4. 0.5 mm
    Show answer

    Answer: B. L.C. = value of one main scale division ÷ number of Vernier divisions = 1 mm ÷ 20 = 0.05 mm. With 10 divisions it would be 0.1 mm.

  3. 3. With the jaws closed, the Vernier zero lies to the right of the main scale zero. What does this mean?

    1. Negative zero error; add the correction
    2. No zero error
    3. The least count has changed
    4. Positive zero error; readings are too large
    Show answer

    Answer: D. A Vernier zero shifted to the right means a positive zero error: every reading is larger than the true value, so the zero correction is negative.

  4. 4. MSR = 6 cm, VSC = 5, L.C. = 0.01 cm and there is a positive zero error of 0.02 cm. What is the correct reading?

    1. 6.03 cm
    2. 6.07 cm
    3. 6.05 cm
    4. 5.98 cm
    Show answer

    Answer: A. Observed reading = 6 + (5 × 0.01) = 6.05 cm. A positive zero error is subtracted: 6.05 − 0.02 = 6.03 cm. Adding it instead would give the wrong 6.07 cm.

  5. 5. With the jaws closed, the Vernier zero is to the left of the main scale zero and the 6th Vernier division coincides (10 divisions, L.C. = 0.01 cm). What is the zero correction?

    1. −0.06 cm
    2. −0.04 cm
    3. +0.04 cm
    4. +0.06 cm
    Show answer

    Answer: C. For a negative zero error count backward: 10 − 6 = 4, so zero error = −4 × 0.01 = −0.04 cm. The zero correction has the opposite sign: +0.04 cm.

Privacy · Terms · Refunds · Delivery