• Practice
  • About 16 min
  • 5 practice questions

Uses of the heating effect, kilowatt hour and electrical safety

Explain why heaters use nichrome and bulbs use tungsten, convert between kWh and joules, calculate electricity bills, and understand short circuits, overloading, fuses and MCBs.

If something looks wrong, please tell us.

By the end of this lesson you can

  • Give examples of devices that use the heating effect and the materials used in them.
  • Use the kilowatt hour (kWh), the 'unit' on an electricity bill, and convert it to joules.
  • Explain short circuit, overloading and how a fuse or MCB protects a circuit.

The heating effect of current is put to work every day in kettles, water heaters, electric irons, cookers and filament bulbs. The same effect, when uncontrolled, can also start fires. This lesson covers both sides.

Devices that use the heating effect

Heating devices use conductors of high resistivity. Electric heaters, cookers and irons use a coil of nichrome, an alloy that has high resistivity and does not oxidise easily when red hot. A filament bulb uses a coiled tungsten wire, which has a very high melting point. When current flows, the tungsten coil becomes extremely hot (around 3400 °C) and glows, giving light; it also gives out some heat. The bulb is filled with an inert gas such as nitrogen, or has a vacuum, so that the filament does not burn away.

The kilowatt hour

The watt is a small unit, so in practice the kilowatt (1 kW = 1000 W) is used. The energy used by a 1 kW device in 1 hour is 1 kilowatt hour (kWh). The electricity bill calls 1 kWh one 'unit' of energy.

1 kWh = 1000 W × 3600 s = 3.6 × 10⁶ J. Energy (kWh) = Power (kW) × Time (h).

Worked example 1: power and current of a bulb

A bulb draws 0.25 A from a 220 V supply. Power = V × I = 220 × 0.25 = 55 W. If it is on for 8 hours a day for 30 days, energy = 55 W × 8 h × 30 = 13200 Wh = 13.2 kWh, that is, 13.2 units.

Worked example 2: a monthly bill

A 2 kW water heater runs for 30 minutes every day for 30 days. Energy = 2 kW × 0.5 h × 30 = 30 kWh = 30 units. If (made-up rate) one unit costs ₹6, the cost = 30 × 6 = ₹180.

Worked example 3: cutting a heater coil in half

A nichrome coil of resistance 55 Ω is connected to 220 V. P = V² / R = 220² / 55 = 48400 / 55 = 880 W. If the wire is cut to half its length, its resistance becomes 27.5 Ω. Now P = 48400 / 27.5 = 1760 W. At the same voltage, halving the resistance doubles the power, so more heat is produced. (Never try this at home: it can overload the wiring.)

Worked example 4: two settings of an iron

An iron on 220 V uses 880 W on its high setting and 440 W on its low setting. High: I = P / V = 880 / 220 = 4 A; R = V / I = 220 / 4 = 55 Ω. Low: I = 440 / 220 = 2 A; R = 220 / 2 = 110 Ω. A larger resistance at the same voltage draws less current and gives less heat.

Short circuit, overloading and protection

A house connection has three wires: live, neutral and earth. The live and neutral wires have a potential difference of 220 V, and the earth wire is connected to the ground.

Dangers and safeguards

  • Short circuit
    • Insulation of live and neutral wires wears off, or a device is faulty
    • The two wires touch, resistance becomes very small
    • A very large current flows and produces great heat
    • Nearby wood, cloth or plastic can catch fire
  • Overloading
    • Too many devices draw current at the same time
    • Example: lights, fans and air conditioners on summer evenings
    • The current exceeds what the wiring or transformer can carry
  • Safeguards
    • Fuse wire: melts when the current is too high and breaks the circuit
    • Miniature circuit breaker (MCB): a switch that opens automatically when the current suddenly rises

Key takeaways: heaters use nichrome and bulbs use tungsten because of their high resistivity and suitable heat behaviour. 1 kWh = 3.6 × 10⁶ J is one unit on the bill; energy in kWh = power in kW × time in h. Short circuits and overloading cause dangerously large currents; fuses and MCBs cut off the supply.

Check your understanding

  1. 1. Why is tungsten used for the filament of an electric bulb?

    1. It has a very low resistance
    2. It has a very high melting point and glows when very hot
    3. It does not conduct electricity
    4. It is the cheapest metal
    Show answer

    Answer: B. The filament must get extremely hot to glow without melting. Tungsten has a very high melting point, so it can glow white-hot.

  2. 2. How many joules are there in 1 kWh?

    1. 1000 J
    2. 3600 J
    3. 3.6 × 10⁶ J
    4. 3.6 × 10³ J
    Show answer

    Answer: C. 1 kWh = 1000 W × 3600 s = 3,600,000 J = 3.6 × 10⁶ J.

  3. 3. A 1.5 kW air conditioner runs for 4 hours. How many units of electricity does it use?

    1. 6 units
    2. 0.375 units
    3. 1500 units
    4. 60 units
    Show answer

    Answer: A. Energy = power × time = 1.5 kW × 4 h = 6 kWh = 6 units.

  4. 4. What happens in a short circuit?

    1. The current becomes zero
    2. The voltage becomes very large
    3. The fuse is removed
    4. The live and neutral wires touch and a very large current flows
    Show answer

    Answer: D. When live and neutral wires come into contact, the resistance in the path becomes very small, so a very large current flows and produces a lot of heat.

  5. 5. A heater draws 5 A from a 220 V supply. What is its power?

    1. 44 W
    2. 1100 W
    3. 225 W
    4. 215 W
    Show answer

    Answer: B. P = V × I = 220 × 5 = 1100 W.

Privacy · Terms · Refunds · Delivery