• Practice
  • About 24 min
  • 5 practice questions

Electric power and energy, emf, internal resistance and combinations of cells

Use P = VI = I²R = V²/R and the kilowatt hour, explain emf and internal resistance and measure r, and find the current from cells in series and in parallel.

If something looks wrong, please tell us.

By the end of this lesson you can

  • Derive P = VI and use P = I²R and P = V²/R.
  • Convert energy in kWh to joules and explain what an electricity bill measures.
  • Predict which bulb glows brighter in series and in parallel.
  • Define emf and internal resistance and use V = ε − Ir and r = (ε − V)R/V.
  • Split the power of a cell between the load (I²R) and the internal resistance (I²r).
  • Find the current from n cells in series and in parallel and say when each arrangement helps.

A circuit is a way of delivering energy: from the chemical energy of a battery or the power station to light, heat and motion in our appliances. This lesson counts that energy and looks at the source itself, which is never perfect.

Electrical power

In a circuit with a battery of voltage V and a resistor, a small charge dQ that passes through the battery from its negative to its positive terminal gains potential energy dU = V dQ, at the expense of the battery's chemical energy. In the resistor it loses the same energy in collisions with the atoms, which appears as heat. The electrical power is the rate at which this energy is delivered: P = dU/dt = V dQ/dt, so P = VI. Using Ohm's law, for a resistor P = I²R = V²/R. The SI unit is the watt: 1 W = 1 J s⁻¹, the power when 1 A flows through 1 V. Because P = I²R, doubling the current through a resistor makes it dissipate four times the power.

Bulbs and appliances are rated with power and voltage, for example 60 W-220 V; the rated voltage usually refers to the AC (RMS) supply. From the rating, R = V²/P. A bulb given much more than its rated voltage may fuse.

Electrical energy

Energy = power × time. With power in watts and time in seconds the energy is in joules, but the practical unit is the kilowatt hour (kWh), commonly called one unit: 1 kWh = 1000 W × 3600 s = 3.6 × 10⁶ J. The electricity board charges for the energy used (kWh), not for the power.

Worked example 1: power and energy

(a) A 1000 W heater runs on 230 V. I = P/V = 1000/230 ≈ 4.35 A and R = V²/P = 230²/1000 = 52 900/1000 = 52.9 Ω. (b) A 1.5 kW water heater is used 2 hours a day for 30 days. Energy = 1.5 kW × 2 h × 30 = 90 kWh = 90 units = 90 × 3.6 × 10⁶ J = 3.24 × 10⁸ J.

Worked example 2: which bulb glows brighter?

Bulbs rated 40 W-220 V and 100 W-220 V are used on a 220 V supply. In parallel each gets 220 V and gives its rated power, so the 100 W bulb is brighter. In series: R₁ = 220²/40 = 1210 Ω and R₂ = 220²/100 = 484 Ω. Total 1694 Ω, so I = 220/1694 ≈ 0.130 A. P₁ = I²R₁ ≈ 0.0169 × 1210 ≈ 20.4 W and P₂ = I²R₂ ≈ 0.0169 × 484 ≈ 8.2 W. Now the 40 W bulb glows brighter: with the same current, the larger resistance takes the larger share of the power. A higher power rating means a brighter bulb only in parallel.

Cells, emf and internal resistance

An electric cell converts chemical energy into electrical energy. A simple cell has two different electrodes dipped in an electrolyte; several cells joined together form a battery. The electromotive force (emf) ε of a cell is the potential difference across its terminals when no current is drawn from it. Despite its name it is not a force; it is measured in volts and gives the work done by the cell per unit charge moved round the circuit. Inside a real cell the electrodes and electrolyte oppose the flow of charge: this is the internal resistance r. A freshly made cell has a low internal resistance, which increases as it ages. For an ideal cell r = 0 and the terminal voltage always equals ε.

Measuring r. First connect a high-resistance voltmeter alone across the cell. It draws almost no current, so it reads ε. Then connect an external resistance R; a current I flows and the voltmeter reads the terminal voltage V = IR, which is less than ε because a part Ir is lost inside the cell: V = ε − Ir, i.e. Ir = ε − V. Dividing by IR = V: r = (ε − V)R/V. The power from the cell is P = Iε = I(V + Ir) = I²R + I²r: I²R reaches the load and I²r is wasted as heat inside the cell. For a good cell r is small and almost all the power reaches the load. The internal resistance of a car battery is why the headlights dim for a moment when the engine is started with them on: the starter draws a large current, and the large Ir drop lowers the terminal voltage.

Worked example 3: internal resistance

A cell of emf 6.0 V is connected to a 5.0 Ω resistor and a current of 1.0 A flows. Step 1: terminal voltage V = IR = 1.0 × 5.0 = 5.0 V. Step 2: r = (ε − V)R/V = (6.0 − 5.0) × 5.0/5.0 = 1.0 Ω (check: Ir = 1.0 × 1.0 = 1.0 V = ε − V). Step 3: power from the cell Iε = 6.0 W; to the resistor I²R = 5.0 W; lost inside I²r = 1.0 W.

Cells in series and in parallel

Series: n cells, each of emf ε and internal resistance r, joined positive to negative, with external resistance R. Total emf nε, total resistance nr + R, so I = nε/(nr + R). If r ≪ R, I ≈ nε/R, n times the current from one cell; if r ≫ R, I ≈ ε/r, no better than one cell. Series connection helps only when the internal resistance is small compared with R. Parallel: n identical cells with all positive terminals joined and all negative terminals joined. The emf stays ε, and the internal resistances are in parallel, r/n, so I = ε/(r/n + R) = nε/(r + nR). If r ≫ R, I ≈ nε/r, n times the current one cell gives into a short circuit; if r ≪ R, I ≈ ε/R, the same as one cell. Parallel connection helps when the external resistance is small compared with the internal resistance.

n identical cells (emf ε, internal resistance r) with load R

  • Series
    • emf nε, internal resistance nr
    • I = nε/(nr + R)
    • Useful when r ≪ R
    • Gives a higher voltage
  • Parallel
    • emf ε, internal resistance r/n
    • I = nε/(r + nR)
    • Useful when r ≫ R
    • Shares the current among cells

Worked example 4: series and parallel batteries

(a) Five cells, each 1.5 V with r = 0.2 Ω, in series with R = 6.5 Ω. Total emf = 7.5 V; total resistance = 5 × 0.2 + 6.5 = 7.5 Ω; I = 7.5/7.5 = 1.0 A. Terminal p.d. of the battery = IR = 6.5 V, so 1.0 V is lost inside the cells. (b) Four cells, each 2.0 V with r = 0.8 Ω, in parallel with R = 0.3 Ω. Internal resistance = 0.8/4 = 0.2 Ω; I = 2.0/(0.2 + 0.3) = 4.0 A, so each cell supplies 1.0 A. A single cell on the same load would give only 2.0/(0.8 + 0.3) ≈ 1.8 A.

P = VI = I²R = V²/R; 1 kWh = 3.6 × 10⁶ J. V = ε − Ir; r = (ε − V)R/V. Series cells: I = nε/(nr + R). Parallel cells: I = nε/(r + nR).

Key takeaways

  • Power is the rate of energy delivery, P = VI; in a resistor P = I²R = V²/R.
  • Bills count energy in kWh (units), 1 kWh = 3.6 × 10⁶ J.
  • In series the higher-resistance (lower-rated) bulb glows brighter; in parallel the higher-rated bulb does.
  • Terminal voltage V = ε − Ir is less than the emf whenever current flows.
  • Series cells for large R, parallel cells for small R.

Check your understanding

  1. 1. An electric iron of resistance 115 Ω is used on a 230 V supply. Its power is:

    1. 460 W
    2. 2 W
    3. 26 450 W
    4. 230 W
    Show answer

    Answer: A. P = V²/R = 230²/115 = 52 900/115 = 460 W. (Check: I = 230/115 = 2 A and P = VI = 230 × 2 = 460 W.)

  2. 2. A 2 kW air conditioner runs for 5 hours. The energy used is:

    1. 10 units and 3.6 × 10⁷ J
    2. 10 J
    3. 10 units and 3.6 × 10⁶ J
    4. 0.4 units
    Show answer

    Answer: A. Energy = 2 kW × 5 h = 10 kWh = 10 units. In joules: 10 × 3.6 × 10⁶ = 3.6 × 10⁷ J.

  3. 3. A cell of emf 2.0 V and internal resistance 0.5 Ω is connected to a 3.5 Ω resistor. The terminal voltage is:

    1. 2.0 V
    2. 0.25 V
    3. 1.75 V
    4. 1.5 V
    Show answer

    Answer: C. I = ε/(R + r) = 2.0/(3.5 + 0.5) = 0.5 A. Terminal voltage V = IR = 0.5 × 3.5 = 1.75 V (or ε − Ir = 2.0 − 0.25 = 1.75 V).

  4. 4. Two bulbs, 25 W-220 V and 100 W-220 V, are connected in series to a 220 V supply. Which statement is correct?

    1. The 100 W bulb glows brighter
    2. Both glow equally
    3. Neither glows
    4. The 25 W bulb glows brighter
    Show answer

    Answer: D. R = V²/P, so the 25 W bulb has four times the resistance (1936 Ω against 484 Ω). In series the same current flows, and P = I²R is larger for the larger resistance, so the 25 W bulb is brighter.

  5. 5. Ten identical cells each of internal resistance r are to drive a current through an external resistance R that is much smaller than r. For the largest current they should be connected:

    1. in series
    2. in parallel
    3. half in series, half reversed
    4. it makes no difference
    Show answer

    Answer: B. In parallel I = nε/(r + nR) ≈ nε/r when r ≫ R, ten times one cell's current. In series I = nε/(nr + R) ≈ ε/r, no better than a single cell. So parallel is better when R is small.

Privacy · Terms · Refunds · Delivery