Magnetic properties of materials and hysteresis
Define magnetising field, permeability, intensity of magnetisation and susceptibility, use B = μ₀(H + M) and μ_r = 1 + χ_m, classify materials as dia-, para- or ferromagnetic with Curie's laws, and read a hysteresis loop to choose materials.
If something looks wrong, please tell us.
By the end of this lesson you can
- Define magnetising field H, permeability μ, relative permeability μ_r and intensity of magnetisation M.
- Use B = μ₀(H + M), χ_m = M/H and μ_r = 1 + χ_m.
- Compare diamagnetic, paramagnetic and ferromagnetic materials.
- State Curie's law and the Curie-Weiss law.
- Explain a hysteresis loop: saturation, retentivity, coercivity and hysteresis loss.
- Choose soft or hard magnetic materials for electromagnets, transformer cores and permanent magnets.
Not all materials respond to a magnetic field in the same way. A copper coin is pushed weakly out of a strong field, aluminium is pulled in weakly, and iron is pulled in strongly. A few quantities let us measure these responses and choose the right material for each job.
Quantities that describe magnetic materials
- Magnetising field H: the field used to magnetise a specimen; a vector with unit A m⁻¹.
- Permeability: a measure of how readily a material lets magnetic field lines pass through it, or how easily it takes up magnetisation. Free space has μ₀; a medium has μ. The relative permeability μ_r = μ/μ₀ has no unit; for vacuum (or air) μ_r = 1.
- Intensity of magnetisation M: the net magnetic moment per unit volume, M = p_m/V, unit A m⁻¹. In a material the electrons' orbital and spin moments normally point randomly; a field induces partial or full alignment. For a bar magnet of pole strength q_m, length 2l and face area A, M = q_m(2l)/(A × 2l) = q_m/A: the pole strength per unit face area.
- Magnetic induction B (the total field inside a specimen): the field μ₀H due to the magnetising field plus the field μ₀M due to the induced magnetism, B = μ₀(H + M).
- Magnetic susceptibility χ_m = M/H: how easily and strongly a material is magnetised. It has no unit.
Combining these: with M = χ_mH, B = μ₀(1 + χ_m)H = μH, so μ = μ₀(1 + χ_m) and μ_r = 1 + χ_m, i.e. χ_m = μ_r − 1.
| Material | χ_m |
|---|---|
| Aluminium | 2.3 × 10⁻⁵ |
| Copper | −0.98 × 10⁻⁵ |
| Diamond | −2.2 × 10⁻⁵ |
| Gold | −3.6 × 10⁻⁵ |
| Silver | −2.6 × 10⁻⁵ |
| Tungsten | 6.8 × 10⁻⁵ |
| Oxygen (1 atm) | 2090 × 10⁻⁹ |
| Carbon dioxide (1 atm) | −2.3 × 10⁻⁹ |
Worked example 1: intensity of magnetisation
A bar magnet of mass 120 g and density 7.5 g cm⁻³ has a magnetic moment of 4.0 A m². Step 1: volume = mass/density = 120/7.5 = 16 cm³ = 16 × 10⁻⁶ m³ = 1.6 × 10⁻⁵ m³. Step 2: M = p_m/V = 4.0/(1.6 × 10⁻⁵) = 2.5 × 10⁵ A m⁻¹.
Worked example 2: susceptibility, permeability and B
A magnetising field of 2000 A m⁻¹ produces a magnetisation of 3.0 A m⁻¹ in a sample. Step 1: χ_m = M/H = 3.0/2000 = 1.5 × 10⁻³ (small and positive: paramagnetic). Step 2: μ_r = 1 + χ_m = 1.0015. Step 3: B = μ₀(H + M) = 4π × 10⁻⁷ × 2003 ≈ 2.52 × 10⁻³ T. Of two materials in the same H, the one with the larger susceptibility is magnetised more easily.
Diamagnetic, paramagnetic and ferromagnetic materials
Diamagnetic materials (bismuth, copper, water). Each electron orbit has a magnetic moment, but in these atoms the moments cancel and the atom has none. An applied field speeds up some electrons and slows down others; by Lenz's law, this induces a small moment opposite to the field, which disappears when the field is removed. In a non-uniform field the material moves from the stronger to the weaker part: it is repelled. Properties: χ_m negative (and small); μ_r slightly less than 1; field lines are pushed out of the material; χ_m nearly independent of temperature. Superconductors are perfect diamagnets: when one is cooled below its transition temperature, magnetic flux is expelled from it (the Meissner effect). Magnetic levitation of trains (maglev) uses electromagnets, one set to lift the train clear of the guideway and another to drive it forward.
Paramagnetic materials (aluminium, platinum, chromium, oxygen). Each atom has a net moment (from orbital and spin moments), but they point randomly and cancel. An applied field partly lines them up, giving a weak moment along the field that lasts only while the field is on. In a non-uniform field they move from weaker to stronger regions. Properties: χ_m positive and small; μ_r slightly greater than 1; field lines are drawn into the material; χ_m falls as temperature rises because thermal motion upsets the alignment. Curie's law: χ_m = C/T, where C is the Curie constant and T is in kelvin; the graph of χ_m against T is a rectangular hyperbola.
Ferromagnetic materials (iron, nickel, cobalt). Atoms have net moments, and a strong interaction arising from electron spin lines them up spontaneously within small regions called domains. Each domain is magnetised, but the domains point different ways, so an unmagnetised specimen has no net magnetisation. In an applied field, (1) domains along the field grow at the expense of the others and (2) other domains rotate towards the field, giving a strong magnetisation along the field. They are strongly attracted into stronger regions of a non-uniform field. Properties: χ_m positive and large; μ_r large; field lines are strongly drawn in. Above a temperature called the Curie temperature T_C, a ferromagnet becomes paramagnetic, and its susceptibility follows the Curie-Weiss law: χ_m = C/(T − T_C).
Three kinds of magnetic material
-
Diamagnetic
- χ_m small and negative
- μ_r slightly less than 1
- Weakly repelled; lines pushed out
- χ_m nearly independent of T
- Bismuth, copper, water
-
Paramagnetic
- χ_m small and positive
- μ_r slightly more than 1
- Weakly attracted
- Curie's law: χ_m = C/T
- Aluminium, platinum, oxygen
-
Ferromagnetic
- χ_m large and positive
- μ_r very large
- Strongly attracted; domains
- Paramagnetic above T_C: χ_m = C/(T − T_C)
- Iron, nickel, cobalt
The textbook also describes magnetometer surveying, which maps small changes in the local magnetic field caused by magnetic minerals in buried structures such as walls, bricks and pottery. According to the textbook, a survey by the Indian Institute of Geomagnetism, Mumbai, helped reveal buried brick structures at the archaeological site of Keezhadi.
Worked example 3: Curie's law
A paramagnetic salt has χ_m = 2.8 × 10⁻⁴ at 300 K. Find χ_m at 350 K. Since χ_m ∝ 1/T, χ₂ = χ₁ × T₁/T₂ = 2.8 × 10⁻⁴ × 300/350 = 2.4 × 10⁻⁴. Warming it reduces its susceptibility.
Hysteresis
For a ferromagnet B does not vary linearly with H, so μ = B/H is not constant. Take an unmagnetised iron specimen and slowly increase H: B rises along a curve until it reaches saturation (the maximum magnetisation possible). Now reduce H to zero: B falls along a different, higher path and does not return to zero. The magnetism left when H = 0 is the retentivity (remanence): the ability to keep magnetism after the magnetising field is removed. To destroy it, a reverse field must be applied; the reverse H needed to reduce B to zero is the coercivity. Increasing the reverse field drives the specimen to saturation in the opposite direction; reducing it and then increasing H forward again completes a closed curve, the hysteresis loop, which corresponds to one cycle of magnetisation. Throughout, B lags behind H: hysteresis means 'lagging behind'.
One cycle of magnetisation round a hysteresis loop
- Saturation H increased: B rises to its maximum.
- Retentivity H reduced to zero: B is still positive (residual magnetism).
- Coercivity Reverse H applied: B falls to zero.
- Reverse saturation Larger reverse H: B reaches its negative maximum.
- Back through zero H reduced and then made positive again: the loop closes.
Then back to step 1: Saturation
Hysteresis loss. Turning the domains round and round wastes energy as heat. The energy lost per unit volume in one cycle equals the area of the hysteresis loop. Materials with a small loop are soft magnetic materials; those with a large loop are hard.
| Property | Soft (e.g. soft iron, mumetal, stalloy) | Hard (e.g. carbon steel, alnico, lodestone) |
|---|---|---|
| Magnetisation after the field is removed | Disappears | Persists |
| Loop area and hysteresis loss | Small, less loss | Large, more loss |
| Retentivity | Low | High |
| Coercivity | Low | High |
| Susceptibility and permeability | High | Low |
| Uses | Electromagnets, solenoid and transformer cores | Permanent magnets |
Choosing materials. Permanent magnets need high retentivity, high coercivity and low permeability (carbon steel, alnico). Electromagnets need high initial permeability, low retentivity, low coercivity and a thin loop (soft iron, mumetal, a nickel-iron alloy). Transformer cores need high initial permeability, large induction and a thin loop of small area so that the energy lost every cycle is small (soft iron).
B = μ₀(H + M); χ_m = M/H; μ_r = 1 + χ_m. Curie: χ_m = C/T. Curie-Weiss: χ_m = C/(T − T_C). Hysteresis loss per cycle per unit volume = loop area.
Key takeaways
- M is moment per unit volume; χ_m = M/H; μ_r = 1 + χ_m.
- Diamagnets: χ_m < 0, repelled; paramagnets: small χ_m > 0; ferromagnets: large χ_m > 0 with domains.
- Paramagnetic χ_m ∝ 1/T; a ferromagnet becomes paramagnetic above its Curie temperature.
- Hysteresis loop: retentivity at H = 0, coercivity at B = 0, loss = loop area.
- Soft materials for electromagnets and transformers, hard materials for permanent magnets.
Check your understanding
-
1. A material has a small negative magnetic susceptibility that hardly changes with temperature. It is:
- ferromagnetic
- paramagnetic
- a permanent magnet
- diamagnetic
Show answer
Answer: D. A small negative χ_m that is nearly independent of temperature is the mark of a diamagnetic material such as bismuth or copper. Paramagnetic and ferromagnetic materials have positive χ_m.
-
2. A ferromagnetic sample has susceptibility 499. Its relative permeability is:
- 500
- 498
- 499
- 1/499
Show answer
Answer: A. μ_r = 1 + χ_m = 1 + 499 = 500.
-
3. The susceptibility of a paramagnetic substance obeying Curie's law is χ at 250 K. At 500 K it is:
- 2χ
- χ/2
- χ
- χ/4
Show answer
Answer: B. Curie's law: χ_m = C/T, so χ ∝ 1/T. Doubling the absolute temperature halves the susceptibility: χ/2.
-
4. A material suitable for making a permanent magnet should have:
- low retentivity and low coercivity
- high permeability and a thin hysteresis loop
- high retentivity and high coercivity
- negative susceptibility
Show answer
Answer: C. A permanent magnet must keep its magnetism (high retentivity) and resist being demagnetised (high coercivity). Low retentivity and coercivity with a thin loop suit electromagnets and transformer cores.
-
5. The energy lost as heat per unit volume of a ferromagnet in one cycle of magnetisation is equal to:
- the coercivity
- the retentivity
- the saturation value of B
- the area of the hysteresis loop
Show answer
Answer: D. The work done in taking the material round one cycle, per unit volume, equals the area enclosed by the B-H hysteresis loop. That is why transformer cores use soft iron with a thin loop.
Sign in to keep track of the lessons you finish.