• Practice
  • About 15 min
  • 5 practice questions

Concentration cells, Ksp and pH from cells: worked practice

Use the Nernst equation for concentration cells, find Ksp from standard potentials, and read pH from a hydrogen electrode, with the shortcuts that save time.

If something looks wrong, please tell us.

A concentration cell has the same electrode material on both sides but different ion concentrations. Its E° is zero, yet it gives a voltage because the system moves towards equal concentration. Together with solubility product and pH from cell data, this is a favourite topic because it uses just one formula in several disguises. We use 0.059 V for 2.303RT/F at 298 K.

The formulas

Formulas for this lesson
SituationFormula
Concentration cell with metal ions M(n+)E = (0.059 / n) log (c right / c left), the more concentrated side being the cathode
Salt electrode (AgX/Ag)E°(AgX/Ag) = E°(Ag+/Ag) + 0.059 log Ksp
Hydrogen electrode against SHEE = 0.059 x pH

In a concentration cell the more concentrated half is the cathode, E is positive, and E falls to zero as the concentrations equalise.

— Rule to remember

Worked example 1: copper concentration cell. Cu | Cu2+ (0.01 M) || Cu2+ (1.0 M) | Cu. Working: n = 2 and the ratio is 1.0 / 0.01 = 100. E = (0.059 / 2) x log 100 = 0.0295 x 2 = 0.059 V. The left half (0.01 M) is the anode and the right half (1.0 M) is the cathode.

Worked example 2: silver concentration cell. Ag | Ag+ (0.001 M) || Ag+ (0.1 M) | Ag. Working: n = 1 and the ratio is 0.1 / 0.001 = 100, so E = 0.059 x 2 = 0.118 V. Note that n = 1 gives twice the voltage of the copper cell for the same ratio.

Worked example 3: Ksp of silver iodide. Given E°(Ag+/Ag) = +0.80 V and E°(AgI/Ag, I-) = -0.15 V (illustrative table values). Working: log Ksp = (-0.15 - 0.80) / 0.059 = -0.95 / 0.059 = -16.1. Ksp = 10^(-16.1) = about 7.9 x 10^-17. The low Ksp corresponds to a much lower E° for the salt electrode. For a 1 : 1 salt, solubility = square root of Ksp = about 8.9 x 10^-9 mol/L.

Worked example 4: pH from a cell. Pt | H2 (1 atm) | HCl (0.01 M) || SHE. Working: for a strong acid, [H+] = 0.01 M and pH = 2. The EMF = 0.059 x 2 = 0.118 V. Conversely, a measured EMF of 0.236 V for another solution means pH = 0.236 / 0.059 = 4.0.

Direction and sign checks

  • If you get a negative E for a concentration cell, swap the halves: the more concentrated side is always the cathode.
  • For Ksp problems, expect a negative log Ksp. A positive value signals an error in subtraction.
  • For the hydrogen electrode, the potential is -0.059 pH as a reduction potential, so higher pH means a lower (more negative) potential.

Worked example 5: dilution effect. In the copper cell of Worked example 1, the 0.01 M side is diluted to 0.001 M. The ratio becomes 1000, so E = 0.0295 x 3 = 0.0885 V. A tenfold dilution on one side raises E by 0.0295 V for n = 2, and by 0.059 V for n = 1.

Traps

  • Dividing by n only for some electrodes. For n = 2, the factor is 0.0295.
  • Using concentrations as ratio left over right when the right is the cathode.
  • Forgetting that the same formula gives zero voltage when the concentrations are equal.

Key takeaways: E = (0.059 / n) log (ratio) with the more concentrated side as cathode; Ksp from the difference of two E° values; pH from E / 0.059 against the SHE.

Check your understanding

  1. 1. What is the EMF of Cu | Cu2+ (0.01 M) || Cu2+ (1.0 M) | Cu at 298 K?

    1. 0.118 V
    2. 0.0295 V
    3. 0.059 V
    4. 0.177 V
    Show answer

    Answer: C. E = (0.059 / 2) log 100 = 0.0295 x 2 = 0.059 V.

  2. 2. In a concentration cell, which half-cell is the cathode?

    1. The more concentrated one
    2. The more dilute one
    3. The left one always
    4. Neither, since E° = 0
    Show answer

    Answer: A. Reduction occurs in the more concentrated half, which removes ions there and moves the system towards equal concentration.

  3. 3. What is the EMF of Ag | Ag+ (0.001 M) || Ag+ (0.1 M) | Ag?

    1. 0.236 V
    2. 0.059 V
    3. 0.0295 V
    4. 0.118 V
    Show answer

    Answer: D. n = 1 and the ratio is 100: E = 0.059 x 2 = 0.118 V.

  4. 4. With E°(Ag+/Ag) = 0.80 V and E°(AgI/Ag) = -0.15 V, what is log Ksp of AgI?

    1. +16.1
    2. -8.05
    3. -16.1
    4. -0.95
    Show answer

    Answer: C. log Ksp = (-0.15 - 0.80) / 0.059 = -16.1.

  5. 5. A hydrogen electrode against the SHE gives 0.236 V. What is the pH?

    1. 2.0
    2. 3.0
    3. 7.0
    4. 4.0
    Show answer

    Answer: D. pH = E / 0.059 = 0.236 / 0.059 = 4.0.