- Practice
- About 15 min
- 5 practice questions
The Nernst equation: cell potential away from 1 M
Apply the Nernst equation at 298 K to electrodes and full cells, write the reaction quotient correctly and use the 0.059/n shortcut.
If something looks wrong, please tell us.
Standard potentials assume every ion is at 1 M and every gas at 1 bar. Real cells rarely are. The Nernst equation corrects E° for actual concentrations, and it is the single most common numerical in this chapter. Most mistakes come not from the formula but from a wrong n or a wrong reaction quotient Q.
The equation and its 298 K form
For a cell reaction with n electrons transferred, E = E° − (2.303RT/nF) log Q. At 298 K the factor 2.303RT/F is about 0.059 V, so:
E = E° − (0.059/n) log Q at 298 K. Q is written like an equilibrium expression: products over reactants, each raised to its coefficient. Solids and pure liquids are left out; gases enter as partial pressures in bar.
For a single electrode written as a reduction, M^n+ + ne⁻ → M, Q = 1/[M^n+], so E = E° + (0.059/n) log [M^n+]. Diluting the ion makes the electrode potential less positive.
Step by step
- Write the balanced overall reaction (anode oxidation plus cathode reduction).
- Find n, the electrons transferred in that balanced equation.
- Build Q from concentrations, with coefficients as powers.
- Compute E°cell, then E = E° − (0.059/n) log Q.
Worked example 1: Daniell cell, dilute copper side
Zn | Zn2+(0.1 M) || Cu2+(0.001 M) | Cu, E° = 1.10 V. Reaction: Zn + Cu2+ → Zn2+ + Cu, n = 2. Q = [Zn2+]/[Cu2+] = 0.1/0.001 = 100, log Q = 2. E = 1.10 − (0.059/2)(2) = 1.10 − 0.059 = 1.041 V, about 1.04 V. The cell potential falls because the reactant ion (Cu2+) is scarce.
Worked example 2: magnesium-copper cell
Mg | Mg2+(0.001 M) || Cu2+(0.0001 M) | Cu, with E° = 0.34 − (−2.37) = 2.71 V. n = 2 and Q = 0.001/0.0001 = 10, so log Q = 1. E = 2.71 − 0.0295 = 2.68 V.
Worked example 3: the hydrogen electrode and pH
For 2H+ + 2e⁻ → H2 at 1 bar: E = 0 − (0.059/2) log (1/[H+]²) = −0.059 × (−log [H+]) = −0.059 pH. In a solution of pH 3, E = −0.059 × 3 = −0.177 V. This straight-line link between potential and pH is how a pH meter works.
Speed method and traps
Every tenfold change in Q changes E by 0.059/n volt: 0.059 V when n = 1, 0.0295 V when n = 2, about 0.0197 V when n = 3. So if Q = 1000 and n = 2, E is lower than E° by 3 × 0.0295 = 0.0885 V without any further working.
- Using the coefficient of a single half-reaction as n instead of the electrons in the balanced overall equation.
- Forgetting the square in Q for reactions such as Zn + 2Ag+ → Zn2+ + 2Ag, where Q = [Zn2+]/[Ag+]².
- Writing Q upside down: products go on top.
- Including solid metals in Q.
Key takeaways: at 298 K, E = E° − (0.059/n) log Q; Q excludes solids; each factor of 10 in Q shifts E by 0.059/n; and the hydrogen electrode gives E = −0.059 pH.
Check your understanding
-
1. For the Daniell cell (E° = 1.10 V) with [Zn2+] = 1 M and [Cu2+] = 0.01 M at 298 K, the cell potential is about:
- 1.16 V
- 1.04 V
- 1.10 V
- 0.98 V
Show answer
Answer: B. Q = [Zn2+]/[Cu2+] = 1/0.01 = 100, log Q = 2, n = 2. E = 1.10 − 0.0295 × 2 = 1.041 V ≈ 1.04 V. 1.16 V comes from writing Q upside down.
-
2. For the reaction Zn(s) + 2Ag+(aq) → Zn2+(aq) + 2Ag(s), the reaction quotient Q is:
- [Zn2+]/[Ag+]
- [Ag+]²/[Zn2+]
- [Zn2+]/[Ag+]²
- [Zn2+][Ag]²/([Ag+]²[Zn])
Show answer
Answer: C. Products over reactants with coefficients as powers; solids Zn and Ag are left out. Q = [Zn2+]/[Ag+]².
-
3. At 298 K, what is the potential of a hydrogen electrode (H2 at 1 bar) dipped in a solution of pH 10?
- −0.59 V
- +0.59 V
- −0.059 V
- 0 V
Show answer
Answer: A. E = −0.059 × pH = −0.059 × 10 = −0.59 V.
-
4. A cell has E° = 0.30 V and n = 2. If Q changes from 1 to 1000, the cell potential at 298 K becomes about:
- 0.12 V
- 0.39 V
- 0.27 V
- 0.21 V
Show answer
Answer: D. log 1000 = 3. E = 0.30 − 0.0295 × 3 = 0.30 − 0.0885 = 0.2115 V ≈ 0.21 V.
-
5. Taking E°(Cu2+/Cu) = +0.34 V, what is the electrode potential of copper in 0.01 M Cu2+ at 298 K?
- 0.40 V
- 0.31 V
- 0.28 V
- 0.34 V
Show answer
Answer: C. E = E° + (0.059/2) log [Cu2+] = 0.34 + 0.0295 × (−2) = 0.34 − 0.059 = 0.281 V ≈ 0.28 V.
Sign in to keep track of the lessons you finish.