Revision notes

Renewable Energy: Practice

The key points, rules to remember, tables and diagrams from all 9 lessons, on one page for quick revision. To keep a copy, use your browser's Print and choose "Save as PDF".

Lesson 1

Classifying energy sources and handling units without slips

1 kWh = 1,000 W × 3,600 s = 3,600,000 J = 3.6 MJ. Energy (kWh) = Power (kW) × Time (h).

Classify by definition, not by how clean a source feels: nuclear is non-renewable, geothermal and tidal are renewable but not solar-derived, and hydrogen and electricity are carriers. Watch for absolute words in statements. Keep power and energy apart, remember 1 kWh = 3.6 MJ, and check every answer's unit before you mark it.

Read the full lesson

Lesson 2

Solar calculations: area, output and real-world losses

Area needed = Target power ÷ (1,000 W/m² × efficiency). Daily energy ≈ Rated power × Peak sun hours × Performance ratio.

Power = irradiance × area × efficiency; area = power ÷ (irradiance × efficiency). Use peak sun hours to turn a day of changing sunlight into one number, and a performance ratio to include losses. PV output falls as cells get hotter. Distinguish PV, which makes electricity directly, from solar thermal and concentrated solar power, which use heat.

Read the full lesson

Lesson 3

Wind calculations: ratios, rotor size and the power coefficient

Power ratio = (speed ratio)³ × (area ratio) × (density ratio). Area ratio = (radius ratio)² = (diameter ratio)².

Use ratios: power changes with the cube of speed, the square of radius or diameter, and in proportion to density. Halve a diameter before squaring. Distinguish power in the wind, the Betz maximum of about 59.3%, and the actual output given by Cp. Above rated speed, output is held constant; at cut-out the turbine stops.

Read the full lesson

Lesson 4

Hydro, pumped storage and tidal: solving for any quantity

Hydro shortcut (g = 10): P in kW = 10 × Q × h × η. Flow Q = P ÷ (ρ g h η); head h = P ÷ (ρ g Q η).

Round-trip efficiency = Energy returned ÷ Energy used for pumping. It is always below 100%.

Hydro power is proportional to flow, head and efficiency, so rearranging is a single division; with g = 10, P in kW = 10Qhη. Pumped storage stores energy and always returns less than it uses; chain efficiencies multiply. Tidal barrage energy grows with the square of the tidal range.

Read the full lesson

Lesson 5

Capacity factor, efficiency chains and levelised cost

Yearly energy = Rated power × 8,760 h × Capacity factor. Capacity factor is about time at full output; efficiency is about conversion losses.

Simple LCOE = Total lifetime cost ÷ Total lifetime energy. Higher capacity factor spreads the same cost over more energy and lowers the LCOE.

Yearly energy = rated power × 8,760 × capacity factor; capacity factor and efficiency are different ideas. Chain efficiencies multiply. LCOE is lifetime cost divided by lifetime energy; raising output with the same cost lowers it, and full calculations discount future amounts.

Read the full lesson

Lesson 6

Biomass, biogas and geothermal: heat, yield and conversion sums

Heat = mass × calorific value (or mass flow × 4.2 × temperature drop for water). Electricity = heat × efficiency. 1 kWh = 3.6 MJ.

Heat from a fuel is mass times calorific value; heat from hot water is flow times 4.2 times the temperature drop. Electricity is heat times efficiency, and 1 kWh is 3.6 MJ. Biogas comes from oxygen-free digestion and is mostly methane. Geothermal heat comes from inside the Earth and can run around the clock.

Read the full lesson

Lesson 7

Storage and off-grid sizing: batteries, autonomy and array size

Wh = V × Ah. Usable energy = Wh × DoD. Hours = usable Wh ÷ load W. Storage needed = daily load × days of autonomy ÷ DoD.

Battery energy is voltage times ampere-hours. Apply depth of discharge to get usable energy, and divide by it when sizing. Series adds voltage, parallel adds ampere-hours, and the energy always adds. Keep kW and kWh apart, and size the array from the daily load, the peak sun hours and the overall efficiency.

Read the full lesson

Lesson 8

Energy payback, avoided emissions and simple payback sums

Payback ideas
IdeaFormulaWhat it answers
Energy payback timeEmbodied energy ÷ yearly energy outputHow long until the system has produced the energy used to make it
Energy return ratioLifetime energy output ÷ embodied energyHow many times over it repays that energy
Simple cost paybackInstalled cost ÷ yearly savingHow long until the money spent is recovered

Avoided CO₂ = energy displaced × (emission factor of displaced supply − lifecycle factor of the new system). Energy payback = embodied energy ÷ yearly output.

Energy payback is embodied energy over yearly output, and the energy return ratio is lifetime output over embodied energy. Avoided emissions are the energy displaced times the emission factor, less the system's own lifecycle emissions. Simple cost payback is cost over yearly saving. Convert units before multiplying.

Read the full lesson

Lesson 9

Mixed practice: hybrid systems, shares, line losses and grid questions

Combined capacity factor = (sum of rated power × CF) ÷ (sum of rated power). Delivered energy = energy sent × (1 − loss fraction).

Work in steps with units, combine capacity factors through average powers, name the base of every percentage, reverse a loss by dividing, and test each statement for the exception. Distinguish variable sources from dispatchable ones.

Read the full lesson

Privacy · Terms · Refunds · Delivery