Mixed practice: hybrid systems, shares, line losses and grid questions
Combine capacity factors correctly, work out generation shares, apply transmission losses, and answer statement questions on variable and dispatchable sources using a short checking routine.
If something looks wrong, please tell us.
Real practice papers rarely keep to one topic. A single question may mix a share of the energy mix, a capacity factor and a loss, or may ask which source can meet demand at night. This lesson gives a checking routine and drills the mixed types. Every figure is illustrative, not an official statistic, and the point is the method.
A four-step routine
- Classify: is the quantity a power (kW, MW) or an energy (kWh, MJ)?
- Choose the method: ratio shortcut if only changes are asked, full formula if absolute values are asked.
- Calculate in steps and write the units beside each number.
- Sense-check: should the answer be larger or smaller than the starting value, and does the unit match the option?
Variable and dispatchable sources
Solar and wind are variable: their output follows sunshine and wind, not demand. A dispatchable source can be turned up or down when the grid needs it. Hydro with a reservoir, biomass, biogas and stored energy are dispatchable; geothermal runs steadily, so it suits constant demand. A grid with a large share of variable sources needs storage, flexible demand, backup plants and links to neighbouring grids. A solar-only system cannot meet night demand without storage, and a statement saying so is false.
Combining capacity factors
Capacity factors cannot simply be averaged. Convert each plant to average power (rated power times capacity factor), add the average powers, and divide by the total rated power. This weights each plant by its size.
Combined capacity factor = (sum of rated power × CF) ÷ (sum of rated power). Delivered energy = energy sent × (1 − loss fraction).
Worked example 1: a hybrid plant
A site has 100 MW of solar with a capacity factor of 20% and 60 MW of wind with a capacity factor of 35% (illustrative). Average powers: solar 100 × 0.20 = 20 MW and wind 60 × 0.35 = 21 MW, so together 41 MW. Total rated power is 160 MW, so the combined capacity factor = 41 ÷ 160 = 0.25625, about 25.6%. Yearly energy = 41 × 8,760 = 359,160 MWh. Averaging the two factors would have given 27.5%, which is wrong because the plants are different sizes.
Worked example 2: shares of the mix
A region generates 100 TWh in a year (illustrative): 12 from solar, 18 from wind, 20 from hydro and 50 from coal. Renewable share = (12 + 18 + 20) ÷ 100 = 50%. Variable renewable share = (12 + 18) ÷ 100 = 30%. If the question asks for solar as a share of renewable generation only, divide by 50, not 100: 12 ÷ 50 = 24%. The base of the percentage decides the answer, so underline it.
Worked example 3: transmission loss
A wind farm sends out 400 MWh in a day and 6% is lost in the lines. Delivered energy = 400 × (1 − 0.06) = 400 × 0.94 = 376 MWh. If the load needs 376 MWh delivered, the farm must send out 376 ÷ 0.94 = 400 MWh, not 376 × 1.06, which gives 398.6. Loss is a fraction of the energy sent, so reverse it by division.
Statement questions
When a statement uses absolute words such as always, never or only, look for the exception: geothermal is not solar-derived, biomass is not automatically carbon-free, pumped storage consumes more than it returns, and variable sources are not dispatchable. A statement that is true of most cases may still be false as written.
Key takeaways
Work in steps with units, combine capacity factors through average powers, name the base of every percentage, reverse a loss by dividing, and test each statement for the exception. Distinguish variable sources from dispatchable ones.
Check your understanding
-
1. A farm has 50 MW with a capacity factor of 24% and another has 30 MW with a capacity factor of 30%. What is the combined capacity factor?
- 26.25%
- 27%
- 54%
- 21%
Show answer
Answer: A. Average powers: 12 MW and 9 MW, total 21 MW. Combined CF = 21 ÷ 80 = 0.2625 = 26.25%. Averaging 24% and 30% gives the wrong 27%.
-
2. A region generates 80 TWh (illustrative): 16 from solar and 24 from wind, the rest from fossil fuels. What share is variable renewable?
- 20%
- 30%
- 50%
- 40%
Show answer
Answer: C. Variable renewable = 16 + 24 = 40 TWh. Share = 40 ÷ 80 = 50%.
-
3. Which of these sources is dispatchable?
- Solar PV in the afternoon, because it is brightest at that time of day
- Hydro with a reservoir, because water can be released when needed
- Wind, because it always blows harder at night than during the day
- Run-of-river hydro, because river flow never changes with the season
Show answer
Answer: B. A reservoir lets operators choose when to generate. Solar, wind and run-of-river output follow nature, not demand.
-
4. A plant sends out 500 MWh and 4% is lost in transmission. How much is delivered?
- 520 MWh
- 496 MWh
- 20 MWh
- 480 MWh
Show answer
Answer: D. Delivered = 500 × 0.96 = 480 MWh. Adding the loss instead of subtracting gives 520.
-
5. Which measure best helps a grid absorb a large share of solar and wind?
- Switching off all dispatchable plants permanently
- Storage, flexible demand and links to other regions
- Building only solar panels in one place
- Removing all transmission lines to avoid losses
Show answer
Answer: B. Variable sources need balancing. Storage, demand that can shift and wider interconnection reduce the mismatch between supply and demand.