- Practice
- About 15 min
- 5 practice questions
Biomass, biogas and geothermal: heat, yield and conversion sums
Solve questions on the heat in biomass, the gas from a biogas plant and the heat carried by geothermal water, using calorific value, yield per kilogram and mass flow times specific heat.
If something looks wrong, please tell us.
Solar, wind and hydro dominate numerical questions, but biomass, biogas and geothermal energy also appear, usually in short calculations with a heat step followed by a conversion step. All the numbers in this lesson are illustrative values chosen to make the arithmetic clear; they are not official figures. The method is what matters: find the heat, apply the efficiency, and convert units.
Biomass: heat from a fuel
The heat released by burning a fuel equals its mass times its calorific value, the heat given per kilogram. Because biomass is usually burned to raise steam for a turbine, the electricity is the heat times the overall efficiency of boiler, turbine and generator. Biomass is renewable only when the plants regrow as fast as they are harvested; burning it still releases carbon dioxide, which the regrowth later takes back.
Biogas: gas from dung and waste
In a biogas plant, microbes break down dung or kitchen waste without oxygen (anaerobic digestion). The gas is mostly methane, the combustible part, with a good deal of carbon dioxide. The slurry left behind, called digestate, is a useful fertiliser. A question normally gives a yield, such as cubic metres of gas per kilogram of dung, and asks you to scale it.
Geothermal: heat carried by water
Hot water or steam from underground carries heat that can drive a turbine or warm buildings. The heat available from a flow of water is mass flow times specific heat times the temperature drop. Take the specific heat of water as 4.2 kJ per kg per kelvin. Because only part of the heat can become electricity, the electrical output is that heat times a conversion efficiency, which is low for moderately hot water. Geothermal plants can run day and night, so their capacity factor is usually high.
Heat = mass × calorific value (or mass flow × 4.2 × temperature drop for water). Electricity = heat × efficiency. 1 kWh = 3.6 MJ.
Worked example 1: a biomass power unit
A small unit burns 1,800 kg of dry crop residue a day. Suppose its calorific value is 15 MJ/kg and the overall efficiency from fuel to electricity is 20%. Heat = 1,800 × 15 = 27,000 MJ. Electrical energy = 27,000 × 0.20 = 5,400 MJ. Convert: 5,400 ÷ 3.6 = 1,500 kWh per day. A common slip is to divide by 3,600 instead of 3.6, which gives 1.5 and the wrong unit.
Worked example 2: sizing a biogas plant
A household needs 6 m³ of gas a day. Suppose each kilogram of fresh dung gives 0.04 m³ of gas and each animal supplies 10 kg of dung a day. Dung needed = 6 ÷ 0.04 = 150 kg a day. Animals needed = 150 ÷ 10 = 15. If the gas carries 20 MJ per cubic metre and the burner is 50% efficient, the useful heat is 6 × 20 × 0.5 = 60 MJ a day. Divide when you want the input for a given output; multiply when you have the input.
Worked example 3: a geothermal flow
Hot water flows at 50 kg/s and is cooled by 60 K in the heat exchanger. Heat extracted = 50 × 4.2 × 60 = 12,600 kW, which is 12.6 MW of heat. If the plant converts 10% of this to electricity, the output is 1.26 MW. The 4.2 is in kJ, so the answer comes out directly in kW. Note that a larger temperature drop or a higher flow gives proportionally more heat.
Traps to avoid
- Calling biomass or biogas 'carbon-free'; they are renewable and roughly carbon-neutral only if regrowth balances use.
- Treating geothermal as solar-derived; its heat comes from inside the Earth.
- Forgetting efficiency and giving the heat as the electrical output.
- Mixing up methane (the fuel in biogas) with carbon dioxide (the other main gas in it).
- Using grams for mass in one place and kilograms in another.
Key takeaways
Heat from a fuel is mass times calorific value; heat from hot water is flow times 4.2 times the temperature drop. Electricity is heat times efficiency, and 1 kWh is 3.6 MJ. Biogas comes from oxygen-free digestion and is mostly methane. Geothermal heat comes from inside the Earth and can run around the clock.
Check your understanding
-
1. A wood-fired unit burns 500 kg of wood with a calorific value of 16 MJ/kg. How much heat is released?
- 31.25 MJ
- 8,000 MJ
- 80,000 MJ
- 800 MJ
Show answer
Answer: B. Heat = mass × calorific value = 500 × 16 = 8,000 MJ. Dividing 500 by 16 gives the wrong 31.25.
-
2. Which statement about biogas is correct?
- Its fuel is mainly hydrogen, made by splitting water in sunlight
- Its fuel is mainly carbon monoxide, made by burning dung fast
- Its fuel is mainly nitrogen, released as the dung dries out
- Its fuel is mainly methane, made by microbes without oxygen
Show answer
Answer: D. Biogas is produced by anaerobic digestion and its combustible part is mainly methane; the other main gas is carbon dioxide.
-
3. A plant digests 80 kg of dung a day and each kilogram yields 0.04 m³ of gas. How much gas is produced per day?
- 3.2 m³
- 32 m³
- 0.32 m³
- 2,000 m³
Show answer
Answer: A. Gas = 80 × 0.04 = 3.2 m³. The value 2,000 comes from dividing 80 by 0.04, which is the wrong operation here.
-
4. Water at 10 kg/s is cooled by 30 K in a geothermal heat exchanger (specific heat 4.2 kJ/kg/K). How much heat is extracted?
- 126 kW
- 12,600 kW
- 1,260 kW
- 12.6 kW
Show answer
Answer: C. Heat = 10 × 4.2 × 30 = 1,260 kW. Keep the temperature drop in kelvin and the specific heat in kJ so the answer is in kW.
-
5. A unit has 36,000 MJ of heat in its fuel and converts 25% of it to electricity. How many kWh of electricity result?
- 9,000 kWh
- 10,000 kWh
- 900 kWh
- 2,500 kWh
Show answer
Answer: D. Electrical energy = 36,000 × 0.25 = 9,000 MJ; 9,000 ÷ 3.6 = 2,500 kWh. The value 9,000 forgets the unit conversion and 10,000 forgets the efficiency.
Sign in to keep track of the lessons you finish.