• Practice
  • About 25 min
  • 15 practice questions

Final self-assessment: renewable energy practice

Test yourself on the whole course: 15 questions with answers explained.

If something looks wrong, please tell us.

Attempt all 15 questions before you look at any answer. They mix ideas from all five lessons and are a little harder than the lesson checks. Work each calculation on paper, choose one option, and only then read the explanation. Note every question you got wrong and revisit the lesson listed at the end.

Final self-assessment

  1. 1. Which statement is correct?

    1. Tidal energy is an indirect form of solar energy, while hydro is not
    2. Hydro is an indirect form of solar energy, while tidal energy is not
    3. Both hydro and tidal energy come from the Earth's internal heat
    4. Neither hydro nor tidal energy is renewable
    Show answer

    Answer: B. The Sun drives the water cycle that fills rivers, so hydro is indirectly solar. Tides come mainly from the Moon's gravity.

  2. 2. A 1.2 kW heater runs 5 hours a day for 30 days. Electricity costs an illustrative ₹6 per kWh. What is the cost?

    1. ₹180
    2. ₹216
    3. ₹10,800
    4. ₹1,080
    Show answer

    Answer: D. 1.2 × 5 = 6 kWh per day; × 30 = 180 kWh; × ₹6 = ₹1,080.

  3. 3. Blue hydrogen differs from grey hydrogen because:

    1. It is made by electrolysis using solar electricity
    2. Most of the carbon dioxide from production is captured and stored
    3. It contains extra oxygen atoms
    4. It is made from biomass
    Show answer

    Answer: B. Both are made from natural gas. Blue hydrogen captures most of the CO2; grey releases it. Electrolysis with renewable power gives green hydrogen.

  4. 4. A 6 kW system is installed where there are 5 peak sun hours and the performance ratio is 0.8. How much energy does it produce in a 30-day month?

    1. 900 kWh
    2. 24 kWh
    3. 720 kWh
    4. 144 kWh
    Show answer

    Answer: C. 6 × 5 = 30 kWh ideal per day; × 0.8 = 24 kWh; × 30 = 720 kWh.

  5. 5. A panel is rated 400 W at 25 °C and loses 0.4% per °C above 25 °C. What is its output at 60 °C?

    1. 384 W
    2. 456 W
    3. 344 W
    4. 260 W
    Show answer

    Answer: C. 60 − 25 = 35 °C. Loss = 35 × 0.4% = 14%. 400 × 0.86 = 344 W.

  6. 6. A roof has 30 m² available. Panels are 18% efficient under 1,000 W/m². What is the largest power that fits?

    1. 3 kW
    2. 5.4 kW
    3. 1.67 kW
    4. 18 kW
    Show answer

    Answer: B. Each m² gives 180 W. 30 × 180 = 5,400 W = 5.4 kW.

  7. 7. Wind speed rises by 50% and the rotor diameter is unchanged. Power in the wind becomes about:

    1. 3.4 times as large
    2. 1.5 times as large
    3. 2.25 times as large
    4. 4.5 times as large
    Show answer

    Answer: A. 1.5³ = 3.375 ≈ 3.4.

  8. 8. A turbine has blades of 30 m, air density 1.2 kg/m³ and wind speed 10 m/s. Taking π = 3.14, what is the power in the wind?

    1. 565.2 kW
    2. 1,695.6 kW
    3. 3,391.2 kW
    4. 1,005 kW
    Show answer

    Answer: B. A = 3.14 × 30² = 2,826 m². P = 0.6 × 2,826 × 1,000 = 1,695,600 W = 1,695.6 kW.

  9. 9. A turbine's rated speed is 12 m/s and its cut-out speed 25 m/s. What is its output when the wind is 18 m/s?

    1. (18 ÷ 12)³ times its rated power
    2. Zero, because it has shut down
    3. Its rated power
    4. Exactly half its rated power
    Show answer

    Answer: C. Between rated and cut-out speeds the blades are adjusted to hold output at rated power. It shuts down only above 25 m/s.

  10. 10. What head is needed for 900 kW from a flow of 3 m³/s at 75% efficiency? (g = 10 m/s²)

    1. 40 m
    2. 30 m
    3. 20.25 m
    4. 400 m
    Show answer

    Answer: A. h = 900,000 ÷ (1,000 × 10 × 3 × 0.75) = 900,000 ÷ 22,500 = 40 m.

  11. 11. A pumped storage scheme returns 60 MWh. Its round-trip efficiency is 75%. How much energy was used for pumping?

    1. 45 MWh
    2. 75 MWh
    3. 135 MWh
    4. 80 MWh
    Show answer

    Answer: D. Energy used = returned ÷ efficiency = 60 ÷ 0.75 = 80 MWh.

  12. 12. A tidal site's range is increased from 3 m to 6 m by a design change, with basin area unchanged. The energy per tide becomes:

    1. 4 times as large
    2. 2 times as large
    3. 8 times as large
    4. 9 times as large
    Show answer

    Answer: A. Energy ∝ h²; (6 ÷ 3)² = 4.

  13. 13. A 20 MW plant produces 52,560 MWh in a year. What is its capacity factor?

    1. 26%
    2. 3.3%
    3. 30%
    4. 60%
    Show answer

    Answer: C. 20 × 8,760 = 175,200 MWh. 52,560 ÷ 175,200 = 0.3 = 30%.

  14. 14. Plant X has a capacity factor of 20% and plant Y of 30%. Both have the same total lifetime cost and the same rated power. How does Y's simple LCOE compare with X's?

    1. Y's is 1.5 times X's
    2. Y's is two-thirds of X's
    3. Y's is 10% lower than X's
    4. They are equal
    Show answer

    Answer: B. Energy is proportional to capacity factor, so Y produces 1.5 times as much. LCOE = cost ÷ energy, so Y's is 1 ÷ 1.5 = 2/3 of X's.

  15. 15. Four stages each have 95% efficiency. The overall efficiency is closest to:

    1. 81%
    2. 95%
    3. 75%
    4. 90%
    Show answer

    Answer: A. 0.95⁴ = 0.9025 × 0.9025 ≈ 0.8145, about 81%. Losses compound, so do not simply subtract 4 × 5%.

Questions 1-3: lesson 1 (classifying sources, hydrogen routes and units). Questions 4-6: lesson 2 (solar area, peak sun hours, temperature losses). Questions 7-9: lesson 3 (wind ratios, rotor size, operating speeds). Questions 10-12: lesson 4 (hydro rearranging, pumped storage, tidal range). Questions 13-15: lesson 5 (capacity factor, levelised cost, efficiency chains).

Privacy · Terms · Refunds · Delivery