• Practice
  • About 16 min
  • 5 practice questions

EDTA titration, dissolved oxygen and BOD calculations

Calculate hardness from an EDTA titration, separate temporary and permanent hardness by titrating before and after boiling, and calculate BOD from dissolved-oxygen readings with a dilution factor.

If something looks wrong, please tell us.

Laboratory questions in water chemistry come in two families: EDTA titrations for hardness, and dissolved-oxygen measurements for BOD. Both reduce to a short formula once the chemistry is clear, and both are full of unit traps. This lesson gives the method, the standard formula and the traps for each.

The EDTA method for hardness

EDTA (ethylenediaminetetraacetic acid, used as its disodium salt) forms stable 1 : 1 complexes with Ca2+ and Mg2+. The water is buffered to about pH 10 with an ammonia–ammonium chloride buffer, at which the complexes form completely and the indicator works properly. The indicator, Eriochrome Black T (EBT), forms a wine-red complex with the metal ions. As EDTA is added it takes the metal ions from the indicator, and at the end point the free indicator shows blue. The colour change is wine red to blue.

Because the reaction is 1 : 1 and CaCO3 = 100 g/mol: hardness (ppm as CaCO3) = V(EDTA, mL) × M(EDTA) × 100 × 1000 ÷ V(sample, mL). Some questions instead give how many mg of CaCO3 one mL of EDTA is equivalent to; then hardness = mL of EDTA × that figure × 1000 ÷ mL of sample.

Worked example 1: total hardness

50 mL of water needs 10 mL of 0.01 M EDTA. Moles of EDTA = 10 × 0.01 ÷ 1000 = 1 × 10^-4 mol, equal to the moles of hardness ions. Mass as CaCO3 = 1 × 10^-4 × 100 g = 10 mg in 50 mL. Per litre: 10 × 1000 ÷ 50 = 200 mg/L = 200 ppm. The formula gives the same: 10 × 0.01 × 100 × 1000 ÷ 50 = 200 ppm.

Worked example 2: permanent and temporary

A second 50 mL portion of the same water is boiled, filtered and made up again to 50 mL; it needs 6 mL of the same EDTA. Permanent hardness = 6 × 0.01 × 100 × 1000 ÷ 50 = 120 ppm. Temporary hardness = total − permanent = 200 − 120 = 80 ppm. Boiling removes only the hydrogencarbonate hardness, so the titre falls.

Dissolved oxygen and BOD

Dissolved oxygen (DO) is usually measured by the Winkler method, an iodometric titration. BOD is found by measuring DO in a diluted sample, keeping the sample sealed in the dark (the standard test runs for five days at 20 °C), and measuring DO again. Polluted water would use up all the oxygen, so a small volume of sample is diluted with oxygen-rich water. Then BOD = (DO at start − DO at end) × dilution factor, where dilution factor = total volume ÷ volume of sample.

Worked example 3: BOD with dilution

5 mL of sewage is diluted to 300 mL. DO at the start is 8.0 mg/L and after incubation 5.0 mg/L. Dilution factor = 300 ÷ 5 = 60. BOD = (8.0 − 5.0) × 60 = 180 mg/L. A student who forgets the dilution factor answers 3 mg/L, which is the usual trap option.

Formulae for this lesson
QuantityFormula
Hardness by EDTAmL EDTA × M × 100 × 1000 ÷ mL sample (ppm as CaCO3)
Temporary hardnessTotal − permanent (after boiling)
Dilution factorTotal volume ÷ sample volume
BOD(DO start − DO end) × dilution factor

Traps to watch

  • Divide by the sample volume in mL and multiply by 1000 to reach per litre; do not stop at the sample volume.
  • EDTA reacts 1 : 1, so molarity is used directly with the CaCO3 molar mass of 100.
  • The EBT colour change is wine red to blue, not the reverse.
  • BOD needs the dilution factor; the raw DO drop is not the BOD of the original sample.

Hardness (ppm) = V(EDTA) × M × 100 × 1000 ÷ V(sample). EBT turns wine red to blue at pH 10. BOD = DO drop × (total volume ÷ sample volume).

— Rule to remember

Key takeaways

EDTA titration gives total hardness; titrating a boiled sample gives permanent hardness, and the difference is temporary. The formula carries a factor of 100 for CaCO3 and 1000 for per litre. BOD is a DO difference multiplied by the dilution factor, so always check how far the sample was diluted.

Check your understanding

  1. 1. 100 mL of water needs 8 mL of 0.02 M EDTA. What is its hardness?

    1. 80 ppm
    2. 160 ppm
    3. 16 ppm
    4. 320 ppm
    Show answer

    Answer: B. 8 × 0.02 × 100 × 1000 ÷ 100 = 160 ppm. (1.6 × 10^-4 mol = 16 mg CaCO3 in 100 mL.)

  2. 2. In the EDTA titration with Eriochrome Black T at pH 10, the colour at the end point changes

    1. from blue to wine red
    2. from colourless to pink
    3. from wine red to blue
    4. from yellow to orange
    Show answer

    Answer: C. EBT is wine red when bound to Ca2+ or Mg2+. When EDTA has taken all the metal, the free indicator is blue.

  3. 3. A sample has total hardness 250 ppm. After boiling and filtering, its hardness is 150 ppm. What is its temporary hardness?

    1. 100 ppm
    2. 400 ppm
    3. 150 ppm
    4. 250 ppm
    Show answer

    Answer: A. Temporary = total − permanent = 250 − 150 = 100 ppm.

  4. 4. 10 mL of waste water is diluted to 250 mL. DO falls from 7.5 mg/L to 4.5 mg/L during the test. What is the BOD?

    1. 3 mg/L
    2. 30 mg/L
    3. 120 mg/L
    4. 75 mg/L
    Show answer

    Answer: D. Dilution factor = 250 ÷ 10 = 25. BOD = (7.5 − 4.5) × 25 = 75 mg/L.

  5. 5. Why is the EDTA titration for hardness carried out at about pH 10?

    1. To dissolve the CaCO3 already formed
    2. So that the metal–EDTA complexes form fully and the indicator changes colour sharply
    3. To kill bacteria in the sample
    4. To convert permanent hardness to temporary hardness
    Show answer

    Answer: B. At about pH 10 the Ca and Mg complexes with EDTA are stable and EBT gives a sharp wine-red to blue change.

Privacy · Terms · Refunds · Delivery